Linomat 5
Instruction manual, March 2016
Page 22
7.5
The parameter type selection dialog
To enter this parameter type selection dialog, press the
DIALOG
key when the instrument display shows the name of the method to be edited (in the method stack dialog).
Page 1: ...INSTRUCTION MANUAL LINOMAT 5...
Page 2: ...and function of keys 12 4 2 Stand alone operation 13 4 3 Aborting an application in progress 14 4 4 Resetting the instrument 14 4 5 Docking the syringe 14 5 Maintenance and trouble shooting 15 5 1 Gen...
Page 3: ...f the instrument Some interior parts of the instrument are under AC power Careless and improper use can cause injury Unauthorized ma nipulations can cause damage This sign indicates on instrument and...
Page 4: ...are parts and consumables supplied by CAMAG only The warranty is voided if parts from other sources are used Check the service manual before you start service to reduce product specific risks The powe...
Page 5: ...and electronic equipment WEEE Directive 2002 96 EC To properly recycle the instrument or parts of it you are requested to send the equipment back to the distribu tor producer or an adequate collection...
Page 6: ...lete The plate support has been secured with foam pieces for ship ment To unlock the plate support remove all foam pieces from the slit in the instrument base Fig 1 The instrument Remove the dosage tu...
Page 7: ...ilation free from acidic alkaline or other gas that may corrode metal or painted surfaces must be secured Further requirements Do not place the instrument in a location where the tempera ture signific...
Page 8: ...Power capacity 20 W Ground terminal A grounded outlet should be within 2 meters of the instrument Gas supply N2 or compressed air Required pressure 4 6 bar 58 87 psi Gas consumption 1 L min 2 4 Gas s...
Page 9: ...f the gas supply and generates an error message if the pressure drops below 3 5 bar during spray on application All valves are controlled in such way that they close if the power fails or the instrume...
Page 10: ...o the spray head 3 and lower the syringe carefully until it rests in the spray head This way the needle is guided through the spray nozzle The volume of the syringe in use must be set in the user dial...
Page 11: ...e to the rear position in order to lower the table Now flip the front ledge 2 of the stage down forward mak ing the plate table freely accessible Place the plate 3 in the rear left corner of the table...
Page 12: ...n holder and in contact with the positioning pins Fig 7 Plate stage with foil 1 foil 2 down holder for foils 3 6 Waste plate To ensure proper spraying all newly filled syringes are started by predosin...
Page 13: ...ng keys are available DIALOG Selects the syringe size selection display System ready or acti vates the manual parameter input mode Method stack ARROW KEYS and Select the next previous parameter or met...
Page 14: ...e RUN key The most recently used method is displayed With the or key you can select another locally stored method Press the DIALOG key to locally change parameters of the se lected method Press the or...
Page 15: ...ies in progress and re initialize the in strument 4 5 Docking the syringe After a method has been started the display will show the re quired volume and the vial or ID of the sample to be used Draw up...
Page 16: ...isplay will now show LINO5 Vx xx xx Setup Mode where x xx xx is the actual firmware version of the Linomat 5 Press the ENTER key to start the Setup dialog Set baud rate Start the Setup dialog accordin...
Page 17: ...r The Teflon tip of the plunger is very sensitive Even slightest scratches can cause a leak Plungers and syringe bodies are exchangeable To fill the sample dosage syringe make sure the needle is not p...
Page 18: ...rners gas flows at high speed and sprays the sample emerging from the needle tip onto the TLC plate Clogged corners make the jet stream irregular Unscrew the jet assembly and wash it with a suitable s...
Page 19: ...Months 695 0015 Syringe 500 l 24 Months 115 0570 Spray nozzle 24 Months 022 7830 Plunger for 100 l syringe 3 Months 022 7831 Plunger for 500 l syringe 3 Months 6 Technical data Power connections 100 2...
Page 20: ...evice is waiting for gas GO TO PARK POSITION Plate table and syringe lever are moved to the parking position INIT TABLE DRIVE Initialization of specified drive 02 12 05 32 PREDOSE 1 3 l Predosage is r...
Page 21: ...e 20 7 2 The System ready dialog 7 3 The syringe selection To enter the Syringe selection press the DIALOG key when the instrument display shows System ready Text Description SELECT SYRINGE 100 500ul...
Page 22: ...Linomat 5 Instruction manual March 2016 Page 21 7 4 The method stack dialog To enter the Method selection dialog Method stack press the RUN key when the instrument display shows System ready...
Page 23: ...al March 2016 Page 22 7 5 The parameter type selection dialog To enter this parameter type selection dialog press the DIALOG key when the instrument display shows the name of the method to be edited i...
Page 24: ...manual March 2016 Page 23 7 6 The parameters input dialog To enter this parameter input dialog press the ENTER key when the display shows the name of the parameter type to be edited in the parameter...
Page 25: ...Linomat 5 Instruction manual March 2016 Page 24 7 7 The Setup dialog To enter the Setup dialog hold down the dialog key wile switch ing on the instrument...
Page 26: ...factor OF is close to zero 2 The max distance sprayed is 50m OFxBand length 37 Selected dosage parameters unrealistic Turret drive speed too high 38 Selected dosage parameters are unrealistic Turret...
Page 27: ......
Page 28: ..._____________________________________________________________ __________________________________________________________________________________ _______________________________________________________...
Page 29: ..._____________________________________________________________ __________________________________________________________________________________ _______________________________________________________...