background image

TLC Sprayer  

Instruction manual, May-18 

4

 

CAMAG only. The warranty is voided if parts from other sources are used. Check 
the service manual before you start service to reduce product-specific risks 

 

If the instrument is found to be defective, it must be switched off and steps must 
be taken to ensure that it cannot be switched on by mistake 

 

If liquids penetrate the inside of the instrument, the power has to be disconnected 
immediately. Small amounts of liquid can be wiped off and/or dried by means of a 
hairdryer, with larger amounts of liquid a service technician has to be called. A test 
of functionality has to be performed in all cases 

 

Carry out all safety checks and the preventive maintenance as recommended by the 
manufacturer in order to assure your personal safety and the full functionality of 
the instrument. Have an authorized service specialist perform any service not 
described by this manual 

 

See original manufacturers' manuals for further safety data on third party 
equipment supplied with the system 

 

The safety of any system incorporate with the equipment is the responsibility of the 
assembler of the system 

 

This symbol indicates that this equipment must not be disposed of as unsorted 
municipal waste but is to be collected separately as electrical and electronic 
equipment (WEEE-Directive 2002/96/EC). To properly recycle the instrument or 
parts of it you are requested to send the equipment back to the distributor, 
producer or an adequate collection system at the end of its life. This will have 
potential effects on the environment and human health 

1.3

 

Parts supplied/Accessories/Consumables 

The following items are supplied with the CAMAG TLC Sprayer (basic setup), order 
number 022.6530: 

Cat. No. 

Quantity 

Description 

100.6531 

Charger unit 

100.6532 

Pump unit with bottle clamp and 
mounted compressed air connector 

746.6535 

Spray head type A 

746.6536 

Spray head type B 

960.0140 

Reagent bottle 100ml with cap 

960.0145 

Reagent bottle 50ml with cap 

B.022.6535 

Instruction manual 

 
 
 
 

Summary of Contents for HPTLC

Page 1: ...INSTRUCTION MANUAL TLC HPTLC SPRAYER...

Page 2: ...essories Consumables 4 2 Unpacking Installation 5 2 1 Installation of pump unit 5 2 2 Connect the spray unit 6 2 3 Hints 6 3 Getting started 6 4 Maintenance Troubleshooting 6 4 1 Maintenance 6 4 2 Dec...

Page 3: ...20 Further this device has passed the CAMAG Quality Assurance tests and has been delivered in safe operation condition For detailed instrument data see chapter technical data Attention For safety rea...

Page 4: ...al See original manufacturers manuals for further safety data on third party equipment supplied with the system The safety of any system incorporate with the equipment is the responsibility of the ass...

Page 5: ...older 022 6539 1 Service Kit comprising 1 compressed air connector 2 gaskets 2 filters bottle holders 2 Unpacking Installation Check with reference to the parts supplied section whether any parts are...

Page 6: ...the capillary tube of the spray head cutting it at 45 angle Do not store the instrument in the charger Use the sprayer until the battery is almost down and then fully re charge it If the instrument is...

Page 7: ...it Mains voltage 100 240 Volt 50 60 Hz Power consumption approx 5 Wh Pump unit Operating voltage 4 8 V DC Inductive charge 45 50 mA 14 16 hours Avoid contact of water or organic solvents with the spra...

Page 8: ...oeco tech de DC TLC Sprayer G W 1 HRB6900 AmtsgerichtWiesbaden Cesch ftsf hrer WolfgangD Fuhrig Marc C Fuhrig Wiesbaclener Volksbank eC BLZ510 900 O0 Konto6 OO5004 Ust tclNr DE I13868290 Product Type...

Page 9: ..._____________________________________________________________ __________________________________________________________________________________ _______________________________________________________...