CALREC
Putting Sound in the Picture
119
HYDRA2 FIXED FORMAT I/O
Power
The operating AC voltage is 100-240V +/-10%, 50-60Hz.
All fixed format Hydra2 I/O units have two IEC AC power inlets and are fitted with dual power
supplies. Units will be fully functional on one PSU, however both should be fed, and where
possible from separate sources to provide redundancy against both PSU failure and external
power loss.
The peak inrush current is limited (cold start). Figures are available for all units. This reduces the
chance of a nuisance trip or fuse blow from power up. The RMS quiescent current figures are
available for all types of I/O box.
All fixed format Hydra2 I/O units require less than 75W of input power. The internal power
supplies fitted have passive filtering (as opposed to active power factor correction) to reduce the
harmonics to within the limits of the standard EN61000-3-2. At the time of writing the standard
does not apply to equipment <75W. If the lower limit is ever reduced the units will be compliant
and as such are future proof.
Heat Output & Efficiency
The Heat output from fixed format Hydra2 I/O units depends on the supply voltage and loading.
Typically it is 0.55 times the RMS VA (Volts x Amperes) at 230V and 0.7 times the RMS VA at
115V. Heat output figures are available for all types of I/O boxes.
The low power PSU efficiency is again dependent on supply voltage and loading, generally
>70%.
Cooling
All fixed format Hydra2 I/O units of 2U or greater are cooled under control with fan assistance.
Operation is not dependent on the fan; it is there to extend the operating life of the unit. There is
an 80mm low power, low speed and low noise fan mounted to the right hand side panel of each
unit venting air. Fan speed is monitored and System Status warnings generated if fans slow or
fail. Air is drawn in through the left hand side panel.
1U Hydra2 I/O boxes do not require fan assistance having sufficient surface area to radiate heat
adequately.
The side panels of all fixed format Hydra2 I/O units should be unobstructed with at least 50mm
(2') clearance to allow airflow. No clearance is required above or below the unit.
I/O units may be mounted in an open bay providing the ambient air temperature is within limits
(see below). The units may also be housed in any air conditioned bay.
Acoustic Noise
<27 dB SPL (A-weighted, 1m from front).
Operating Ambient Air
Temperature
0ºC - 35ºC.
Relative Humidity
5% - 80% Non-condensing.
Summary of Contents for Apollo
Page 5: ...calrec com Putting Sound in the Picture APOLLO INFORMATION...
Page 9: ...calrec com Putting Sound in the Picture APOLLO CONTROL SURFACE...
Page 29: ...calrec com Putting Sound in the Picture APOLLO PROCESSING CORE...
Page 35: ...calrec com Putting Sound in the Picture APOLLO CONNECTION INFORMATION...
Page 59: ...calrec com Putting Sound in the Picture APOLLO EXTERNAL CONTROL...
Page 72: ...72 APOLLO Digital Broadcast Production Console 72 APOLLO Digital Broadcast Production Console...
Page 73: ...calrec com Putting Sound in the Picture APOLLO SETUP AND CONFIGURATION...
Page 93: ...calrec com Putting Sound in the Picture APOLLO PANEL OPTIONS...
Page 115: ...calrec com Putting Sound in the Picture APOLLO SPECIFICATIONS...