background image

GB

BS...IMAT  Rev2 - Operating Instructions

Page 3 / 12

1.2. Manufacturer name and address

Manufacturer’s name:  

Calpeda Ltd

Address:  

6-8 Wedgwood Rd Ind Est 

    

Bicester OX26 4UL, UK

 www.calpeda.co.uk
1.3. Authorized operators

The  product  is  for  qualified  operators  upon  final 

users and specialized technicians. (see above).

i

  It’s  forbidden  for  the  final  user  to  do  any 

operation reserved only for the authorized 

technicians.  The  manufacturer  isn’t 

responsible for the related damage done by 

missing this prohibition. 

1.4. Warranty

Warranty covers all defects within the booster set 

resulting from faulty workmanship and/or materials 

for a period of two years from the date of installation 

or 30 months from the date of dispatch from our 

production centre, whichever is the shorter.

i

  The warranty covers the replacement or 

repair of the faulty parts and labour to do so. 

It does not cover any secondary loss, costs 

associated with the removal, returning or 

refitting of the set.

Under no circumstances should the faulty 

equipment be dismantled. Failure to comply could 

invalidate the warranty.

The warranty may be lost in these cases:

-  Whenever the use of this product is different from 

its intended use described in this manual.

-  Defects arising from incorrect installation and/or 

operation.

-  In case of modifications or customizations made 

without the authorization of the manufacturer.

-  In case of technical assistance operations made 

by non-authorized personnel.

-  In case of missing maintenance (described in this 

manual).

1.5. Technical assistance

Any further information on documents, service 

assistance, and device parts, please contact:

Calpeda Ltd

6-8 Wedgwood Rd Ind Est, 

Bicester OX26 4UL, UK

T:+44 1869 241441 F: +44 1869 240681 

E: [email protected]

W: www.calpeda.co.uk

2.  TECHNICAL DESCRIPTION

Constant pressure booster sets with built-in 

frequency converter made with multiple pumps, 

ball valve, non-return valve and pressure gauge on 

discharge side, ball valve on suction side.

EASYMAT – Domestic and  Commercial use

I-MAT – Domestic, commercial and industrial

2.1. Intended use

For clean liquids: non-explosive and non-flammable, 

non-hazardous for health or the environment, non 

aggressive for booster set materials, not containing 

abrasives, solid or fibrous particles.

Liquid temperature from 0 °C to + 40 °C in line with 

the regulation.

2.2. Expected improper use

The device is designed and manufactured 

exclusively for the purpose described in sec. 2.1.

  Improper use of the device is forbidden, as 

is use under conditions other than those 

indicated in these instructions.

  Booster sets must not be used in hazardous 

areas as they could cause an explosion if 

there  is  the  danger  of  ignition  by  a  flame 

path. 

It will be not accepted liability for the use of our 

sets with liquids which could be construed as being 

hazardous to health either by touch, ingestion, or 

inhalation of fumes or gases given off by the liquid.

Calpeda cannot be held responsible for failures 

or injuries related to the inobservance of the 

restrictions described.

2.3. Marking

The following picture is a copy of the name-plate.

1) Type

2) Working pressure

3) Total power

4) Control panel

5) Weight

6) Certifications

7) Serial number

3.  TECHNICAL CHARACTERISTICS

Dimensions and weight (see technical catalogue).

Protection IP54 (depending on pump model)

Supply voltage / Frequency:

EASYMAT  230 V1~50 Hz

I-MAT 400V3~50 Hz

Sound pressure: refer to individual pump data

Maximum permissible pressure: up to 10 bar 

depending on model.

3.1. Operating conditions

The product works properly only if the followings 

conditions are respected.

Floating voltage rate: +/-10% max

Floating frequency rate: +/- 4% max

Ambient temperature: up to 40°C

Relative Humidity: up to 90% without condensing

Altitude: Below 1000 m inside a building.

i

  Booster sets must be used in conjunction 

with a cold water storage tank and must not 

be connected direct to mains in-line with 

water byelaw regulations.

3.2. Product overview

The booster set is generally made of:

Summary of Contents for Easymat

Page 1: ...Cold Water Booster Sets Easymat IMAT OPERATING INSTRUCTIONS Page 2 English...

Page 2: ...l working pressure chapter 3 1 The type and section of the power cable chapter 6 5 The type of electrical protection to be installed chapter 6 5 1 1 Symbols To improve the understanding of the manual...

Page 3: ...valve non return valve and pressure gauge on discharge side ball valve on suction side EASYMAT Domestic and Commercial use I MAT Domestic commercial and industrial 2 1 Intended use Forcleanliquids no...

Page 4: ...oduct manuals supplied in the pack 5 TRANSPORT AND HANDLING During transport do not stack heavy objects on it Make sure that during transport the vehicle that is used is big enough for the total dimen...

Page 5: ...set should be secured to rest clamps so that they do not transmit stress strain or vibrations to the booster set The pipe diameters must not be smaller than the booster set connections Isolation valv...

Page 6: ...uction pipeline With sufficient head the water will overcome the resistance of the non return valve fitted in the suction side of the pump and will fill the pump body Otherwise prime the pump with the...

Page 7: ...ntenance and inspection OFF Before every maintenance operations disconnect the power supply and make sure that the device could not accidentally operate Close the suction and delivery gate valves and...

Page 8: ...BS IMAT Rev2 10 ELECTRICAL DIAGRAM EASYMAT1 2 Frequency converter EASYMAT 1 Supply 50 60Hz 8 9 10 11 8 9 10 11 8 9 10 11 EAS MCB2 ISL MCB1 YMAT 2 2 Panel Type QTE2 10M QTE2 16M QTE2 20M MCB 1 2 10A 16...

Page 9: ...LECTRICAL DIAGRAM EASYMAT1 3 Frequency converter EASYMAT 1 1 2 3 Supply 50 60Hz 8 9 10 11 8 9 10 11 8 9 10 11 8 9 10 11 EASYMAT 2 EASYMAT 3 Panel Type QTE3 10M QTE3 16M QTE3 20M MCB 1 2 3 10A 16A 20A...

Page 10: ...A 1A 2A 2A 2A 1A 1A 1A 2A 2A 2A E U V W E U V W 1 2 1 3 9 10 7 8 9 7 8 9 2 3 4 2 3 4 Float 1 Float 2 Remote ON OFF Common N O N C Common N O N C Common N O N C Common N O N C Pump 1 Pump 2 Pump 1 Alar...

Page 11: ...E U V W 1 2 1 3 9 10 7 8 9 7 8 9 7 8 9 2 3 4 2 3 4 2 3 4 Float 1 Float 2 Remote ON OFF Common N O N C Common N O N C Common N O N C Common N O N C Common N O N C Common N O N C Pump 1 Pump 2 Pump 3 Pu...

Page 12: ...mity with the standards laid down therein The manufacturer also declares that the following harmonised international standards have been applied EN ISO 12100 2010 EN 809 1998 A1 2009 EN 60204 1 2006 A...