INST
ALLA
TION
HEATING ELEMENTS
1.Attach heating elements to the tank sidewall using the adhesive backing provided.
Hold the
elements in position then, working around the tank, peel the release paper from them and
press lightly into position.
2.Repeat step 1 for each heating element.
3.Once all of the elements are in place properly, firmly press the element/adhesive into place
securing the elements to the tank.
4.Seal the edges of each element with duct tape.
This will ensure that insulation does not come
between the elements and the tank wall which could impede heat flow into the tank.
Do not install the
elements over
manways, fittings,
pipes, ribs, chan-
nels, insulation or anything other than
the smooth tank wall itself. Ensure that
the entire element will be in smooth,
direct contact with the surface of the
tank.
Do not fold or
overlap the heat-
ing elements.
Note
Press the elements lightly in place at this time in case they need to be reposi-
tioned later.
Note
The heating elements are most effective when placed as close to the bottom of
the tank as possible. This will allow warmer material to flow upward, promoting
convection currents and more even internal heating.
Note
If any heating elements need to be moved, do so before the adhesive sets up.
After a short time the heating elements can not be removed without seriously
damaging them.
Note
Do not install heating elements when the air and/or tank temperature is below
35°F/2°C. Below this temperature the adhesive backing initially may not stick properly.
Once the heating elements have been secured in place for at least 24 hours, tempera-
tures at or below 35°F/2°C will not adversely affect the adhesive.