CALORIQUE Snow & Ice CM1020 Installation Manual Download Page 4

• Replace the skid plate and secure in place using the supplied

stainless steel screws.

Wire Skid Plates Together. (If more than one plate is used.)

Using the supplied tap connectors, wire the skid plates together.

Using the following figure as a guide, route conduit into the

junction box on each plate and splice the three legs of electrical

power together using the supplied waterproof connectors.

Tap wires between each plate using the connectors within the

attached junction box.

Secure Conduit in Place.

Use a recognized method for securing the conduit.

Attach Cover Plate.

Apply a continous bead of exterior grade silicone sealant along

the inside edge of the cover plate, then screw the plate to the

junction box using the included screws.

Check Resistance. 

Using an accurate ohm meter, test each

skid plate to ensure that it is within the limits shown on the

specification sheet. This test confirms that the plates were not

damaged during installation.

Complete Electrical Connections.

• Connect Skid Plates to the Control System.

Following the manufacturer’s instructions for the control, con-

nect the skid plates to the control.

• Supply Power to the Control.

• Test the System Operation.

Turn on the system and ensure that it is drawing the correct

amount of current. The current draw for your system is listed

on the order sheet that comes with the system.

Operation

NOTE: 

Do not operate the system when the air temperature is above

50°F (10°C). Operation above this temperature may overheat the ele-
ments and present a shock hazard.

When using the CalorIQue snow sensor, the skid plates will

heat up automatically when needed. No user intervention

should be required. See the control’s operations manual for

additional information.

When using an on/off switch as the sole control, turn on the

system when snow or icy conditions are expected.

Copyright © 2002-2004 CalorIQue, Ltd. 
All rights reserved.
Printed in USA

CalorIQue, Ltd.

2380 Cranberry Highway
West Wareham, MA 02576
USA
+1 508.291.4224 voice

+1

800.922.9276

+1 508.291.2299 fax
www.calorique.com
[email protected]

Line

Line

Ground

To Next
Plate

To Element

(internal)

To Previous
Plate or
Junction Box