WARNING: Isolate machine electrically before entering machine
or removing panels.
The user check list should be carried out before initiating a service call.
Do not attempt to interfere with any internal control settings as these
have been factory calibrated and sealed.
Only a competent electrician should attempt to rectify electrical supply
problems.
The refrigeration circuit can only be worked on by an authorised/
competent technician in accordance with EU 517/2014.
If in doubt or if advice required, contact the Dantherm Group UK
Service Department. Telephone (01621) 856611 (option 4).
USER CHECK LIST 30/45/70BHC
LAMP
ACTION
MODE
UNIT DOES NOT OPERATE
HEAT
COOL
ALL LAMPS
OFF
Check mains supply - external fuses - isolator etc check internal
control M.C.B
P
P
MAINS
RED
ON
Check thermostat set point.
‘Standby’ switch is set to run (1)
P
P
TEMP O.K
GREEN
OFF
P
P
WATER FLOW OK GREEN
ON
P
P
OTHER LAMPS
OFF
P
P
MAINS
RED
ON
Check air flow is not restricted
P
P
FAULT
AMBER
ON
Check fan and compressor M.C.Bs and if fitted soft start reset
button. Check interlock if fitted.
P
P
WATER FLOW OK GREEN
ON
OTHER LAMPS
OFF
Check HP and LP cutout switches and reset (red buttons below
console thermostat) Check compressor MCBs
P
P
FAN ON COMPRESSOR OFF
MAINS
RED
ON
CHILL
RED
OFF
CHILL LIMIT
AMBER
ON
Check thermostat set point not set too low.
P
WATER FLOW OK GREEN
ON
Check that 12 hours elapsed since power up.
OTHER LAMPS
OFF
MAINS
RED
ON
HEAT
RED
ON
Unit on defrost (normal) - check air flow not restricted.
P
CHILL
RED
ON
P
DEFROST
WHITE
ON
Ensure temperature is above 9ºC for standard model.
P
P
WATER FLOW OK GREEN
ON
OTHER LAMPS
OFF
UNIT OPERATES INTERMITTENTLY
MAINS
RED
ON
Check water flow is not restricted
P
P
HEAT
RED
ON/
OFF
and that electrical supply is adequate
P
P
CHILL
RED
ON/
OFF
P
P
FAULT
AMBER
ON/
OFF
WATER FLOW OK GREEN
ON/
OFF
Check water flow is adequate
P
P
MAINS
RED
ON
FAULT
AMBER
ON
Check water flow not restricted
P
P
WATER FLOW OK GREEN
OFF
Check water flow is adequate
P
P
OTHER LAMPS
OFF
HEAT PUMP MALFUNCTION
29
SD566250 ISSUE 35
Summary of Contents for Pro-Pac 140
Page 1: ...Pro Pac system Pro Pac 30 45 70 90 140HC Owner installation manual SD566250 issue 35...
Page 2: ...2 SD566250 ISSUE 35 PR0 PAC SYSTEM OWNER INSTALLATION MANUAL...