background image

Page9

F4

CONTROL FUSE 10A 

B 0,5

1A

B 2,5 

B 2,5 

B 2,5 

R/BL 0,5 

B 0,5 

B 0,5 

GR

N(

G

R

N/

Y

E

L

BLK 

D355552 

LABEL D64355553 

D355552 

WIRING DIAGRAM 

PAC320DX/HEX320D

ISSU

E 2 

HEX UNIT 

--- 

CJW 19:01:02 

NTS 

AIR STAT 

3 POSN SWITCH 

A B 

21 

DELAY TIMER 

1 4 

2 3 

DEFROST STAT 

FAN MOTOR 

SOLENOID VALVE 

CONDENSATE 

FLOAT SWITCH 

HIGH LEVEL 

FLOAT SWITCH 

LOW LEVEL 

MAINS 

DEFROST 

CHILL 

BR 2,

B

 2.

BR 2,5 

B 0,5 

B 0,5 

CONTACTOR  B 

AUX 

A1 

22 

BR 0,5 

BR 

B 0,5 

B 0,5 

BR 0,5 

R/BR 0,5 

W

 0,

BL/W 0,5 

RELAY No 1 

W

/BL

 0,

P 0,5 

P

 0,

P 0,5 

O/

B

L

 0

,5

 

O 0,5 

O 0,5 

GR/B 0,5 

W/

R

 0

,5

 

W/

R

 0

,5

 

B 0

,5 

G/

R 0

,5

 

R 0,5 

W 0

,5

 

GR 0,5 

GR 0

,5

 

BR 0,5 

BR

 0

,5 

B

R

 1,

BLACK

BROWN 

BR 0,5 

BLUE

R 2

,5

 

BL

 2,

5

 

FLYING LEAD 

FLYING LEAD 

SUMP 

GREY

GREY

GREY

GREY

R/

B

R

 0

,5

 

BR

 0,

W

/BL

 0,

B 0

,5 

BR

 2

,5 

B 2

,5 

W/R 0,5 

B 0,5 

W/R 0,5 

G/Y 1,0 

G/Y 1,0 

B 0,5 

B 0

,5 

W/

R

 0

,5

 

W

 0,

O 0,5 

BR

 0,

B 0,5 

BR 

G/Y 1,0 

PUMP 

W/R 0,5 

W 0,5 

G/

R 0

,5

 

G

/R

 0,

B 0

,5

 

BR

 0

,5 

B

R

 0,

FAN ONLY 

COOL 

W/BL LINK 

GR 0,5 

B 0,5 

WATER PUMP 

BR 1,0 

N/C 

AT 

S1 

CL DL RL 

FT 

MV 

MP 

FS1 

FS2 

NOTE ORIENTATION OF SWITCHES 

B 0,

A2 

W 0

,5

 

2,5 

0,5 

0,5 

B 0,

5

 

8 COM 

7 N/C 

6 N/O 

5 FAULT SIGNAL 

4 OUT 

3 SIGNAL IN 

2 L 

1 N 

B 0

,5 

B 0,

PUMP CONTROLLER 

PUMP 

FAN MOTOR 

CA

PA

C

IT

O

CA

P

A

C

IT

O

BASE PLATE 

EARTH 

M

A

IN

S

 SUPPL

Y

 

L1

 

L2

 

GND 

WHT 

BLK 

GRN 

GRN/YEL 1,50 

BRN 

BRN 

WHT 1,00 

PR

OT

EC

TO

R

 

MAINS 

START 

NO

 

NC

 

WATER STAT 

BLK 

R

E

D(

NO

T

 U

S

E

D

WH

T

 

BL

K

 

WIRED TO RUN COUNTER CLOCKWISE 

R

EVE

R

S

IN

G PLU

G

 

YEL(WHT) 

BL

K

 

GR

N(

GR

N

/Y

E

L)

 

/WHT 

BLK 

T Z 

F2 

CONTROL FUSE 10A 

CONDENSATE FUSE 1A 

BR 0,5 

BR 0,5 

G/R 0,5 

F1 

F3 

FLYING LEADS 

BLK 1,00 

WHT 

YEL(WHT) 

BLK 

BLK 

GRN 
GRN (GRN/YEL) 

GRN 

G/Y

2 POSN SWITCH 

FAN SPEED 

S2 

HIGH

LOW

TOLERANCE UNLESS SPECIFIED

HOLES TO BS 4500 

E12

INSPECTION LEVEL

DIMS

SHT No.

CONT'

DRAWN

DRG No.

APPROVED

DATE

SCALE

IF IN DOUBT ASK

TITLE 

DRG No.

Summary of Contents for PORTA TEMP 240

Page 1: ...RE APPROPRIATE ACCESS TO THE FILLING POINT FOR THE WATER CIRCULATING SYSTEM IS REACHED BY THE REMOVAL OF THE FILLER ACCESS PLATE IN THE ROOM UNIT BACK PANEL 2 WHEN REMOVING THE UNIT FROMAN INSTALLATIO...

Page 2: ...Page 2 BLANK PAGE...

Page 3: ...units are supplied with a NEMA power plug attached to the power supply cord They require a 208 230volt 1 phase 60Hz supply with the following appropriately protected current rating PAC 240 20 AMPS PAC...

Page 4: ...GHT AMBER HIGH PRESSURE RE SET LOW PRESSURE RE SET DEFROST LIGHT WHITE OFF POSITION 7 OPERATING INSTRUCTIONS The Control Panel on the room unit is illustrated below see Fig 3 a Revolve thermostat knob...

Page 5: ...SCREW RETAINERS AND OPEN PANEL TO REMOVE FILTERS 9 MACHINE NOT WORKING ONLY A COMPETENT ELECTRICIAN SHOULD ATTEMPT TO RECTIFY ELECTRICAL SUPPLY PROBLEMS DO NOT REMOVE ANY PANELS FROM THE MACHINE Probl...

Page 6: ...6 97 GSM 23 6 97 952 GSM 23 1 98 961 GSM 4 6 98 961 GSM 3 12 98 JAC 1004 1050 CJW 29 06 04 C N APPD DATE 1084 CJW 15 04 05 C L H C L H LP SWITCH HP SWITCH TERM BLOCK EARTH STUD FAN CAP COMP RUN CAP H...

Page 7: ...OAT SWITCH LOW LEVEL SCHWIMMERSCHALTER NIEDRIGER STAND INTERRUPTEUR A FLOTTEUR NIVEAU BAS C4 SUPPRESSOR SUPPRESSEUR ENTSTORUNGSELEMENT D355550 WIRING DIAGRAM PAC240 HEX240 TOLERANCE UNLESS SPECIFIED H...