23
1005494 ISS 1
9�0� DATASHEETS
MODEL
UNITS
IPT8 ALX
IPT12 ALX
IPT16 ALX
IPT22 ALX
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity
kW
9.5
13.0
20.0
25.0
COP range
13.2-5.4
13.5-5.6
13.5-5.7
13.8-5.8
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
kW
7.0
9.5
13.5
17.0
COP range
6.9-4.2
7.0-4.0
7.0-4.2
7.2-4.0
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity (kW)
3.9
5.2
7.4
9.4
TECHNICAL SPECIFICATIONS
Operating air temperature
°C
-5°C to 43°C
Rated input power
kW
0.3-1.79
0.40-2.38
0.57-3.21
0.69-4.25
Rated input current
A
1.38-7.58
1.82-10.8
2.60-14.61
3.16-19.32
Maximum input current
A
9.5
12.5
19.5
20
Rated RCD
A
30
30
30
30
Rated fuse/MCB type C
A
16
25
25
25
Sound level at 10m
dB(A)
19.6-31.5
21.9-32.0
24.3-36.1
24.9-36.7
Advised water flow rate
m
3
/h
3.0-5.0
4.0-6.0
7.0-10.0
10.0-12.0
Pool water connections
Inches
1½” or 50mm Female
Hermetic system
Refrigerant charge R32
kg
0.6
0.9
1.1
2.0
Net dimensions (w x d x h)
mm
864 x 359 x 648 864 x 359 x 648 954 x 359 x 748 1084 x 429 x 948
Packed dimensions (w x d x h)
mm
950 x 375 x 675 950 x 375 x 675 1040 x 375 x 775 1130 x 445 x 985
Net weight
kg
47
49
68
90
NOTES:
Heat pump performance parameters are subject to change without notice. Always refer to the nameplate.
Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.