10
3. Part : INSTALLATION AND PREPARATION FOR USE
This modern, functional and practical oven, that was manufactured with parts
and materials of the highest quality, will meet your cooking needs in every
aspect. You must read this manual so that you don't have any problems in the
future and to achieve satisfactory results. The following information is the
required rules for right installation and service processes. It must be read
especially by the technician who will install the appliance
Contact AN Authorized Service Company For Installation Of Your Oven
Your oven must be set up and used in a place where it will always have
ventilation
to
the outside,
.
3.1 E
nvironment
where your appliance will be installed
•
.
•
For rooms with a volume of less than 5 m
³
- permanent ventilation of 100
cm
²
is required.
•
For rooms with a volume of between 5 m
³
and 10 m
³
a permanent
ventilation of 50 cm
²
will be required unless the room has a door which
opens directly
in which case no permanent ventilation is
required.
For rooms with a volume greater than 10 m
³
- no permanent ventilation is required.
Pay attention: Regardless of room size, all rooms containing the appliance must
have direct access to the outside air via an openable window or
equivalent.
Emptying of the Burned Gases from Environment
Cooking appliances that operate with gas, exhaust the burned gas wastes out
directly to the outside or through cooker hoods that are connected to a chimney
that opens directly to the outisde. If it seems impossible to install a cooker
hood, it is necessary to set an electric fan on the window or wall that has
Air inlet section
2
min. 100cm
Air inlet section
2
min. 100cm
Figure 1
Figure 2