10
The selection of fuse and breaker must strictly follow the data in table 3.
Choose the suitable power wire according to table 3 and local codes.
Take off the service cover of the generator, insert the 3-core power wire (single phase, 240V
,
60Hz ) into the hole at the back of the generator case and connect to the correct terminal. (Refer to
figure 9
,10
).
Single phase, 240V
,
60Hz power supply:
connect one of the live wires to the terminal
labeled as “
L1
” ; connect the other live wire to the terminal labeled as “
L2
” ; and connect the
ground wire to the terminal labeled as
“
”.
240VAC60Hz