32
Connecting a 12-pole plug connector
Connect the cable of the 12-pin connector (fig. 13) according
to the circuit diagram (fig. 14) to the supply battery (battery II),
the starter battery (battery I) and the dynamo.
23
19
27
16 20 24
17
25
21
18
26
22
Make sure that the contact pins engage secure-
ly with the plug connector! Loose contact pins
can lead to malfunctions or short-circuiting. The
fuses protect the circuits.
Fig. 13: 12-pole connector
– Connect the negative charging current line for the battery II
(blue 6 mm²) on the device (contacts 24 and 25) and the
negative terminal of the battery II.
– Connect the positive charging current line for the battery II
(red 6 mm²) on the device (contacts 16 and 17) and the
positive terminal of the battery II. If the lines are over 1 m in
length, this line needs to be equipped with a fuse near the
positive terminal of the battery II!
For the power supply EVS 36/20-DS/IU with a 30 A fuse.
For the power supply EVS 36/30-DS/IU with a 40 A fuse.
– Connect the positive line (red 10 mm²) on the device
(contacts 20, 21 and 22) and the positive terminal of the
battery II. This line must be fitted with a 40 A fuse near the
positive terminal of the battery II!
– Connect the measuring line (red 0.75 mm²) to the B+ input
on the device (contact 19) and the positive terminal of the
battery II. This line must be fitted with a 2 A fuse near the
positive terminal of the battery I!
– Connect the positive line of the battery I (red 6 mm²) on the
device (contacts 26 and 27) and the positive terminal of the
battery I. This line must be fitted with a 40 A fuse near the
positive terminal of the battery I!
– Connect the line (brown 0.75 mm²) to the D+ input on the
device (contact 18) and the D+ contact to the dynamo. This
line must be fitted with a 2 A fuse near the dynamo!
Insert the 12-pole plug connector into the socket provided on
the device (fig. 4, pos. 9).