![background image](http://html1.mh-extra.com/html/calimet/cm5-dcfp/cm5-dcfp_instruction-manual_3443906017.webp)
16
1. CL-DELAY: Gate Closing delay, switch to ON position, turn timer to 1- 6 seconds.
2.TIMER: 1-60 Timer: Auto activated to close gate upon set time ( 1~ 60 seconds).
3. OSC: Remote control priority. Allow remote control to direct gate movement whenever gate is
moving in any direction. Use first signal to stop gate, use second signal to move gate to opposite
direction.
4. 1 PASS: Anti-tailgating system. It corresponds to underground safety loop. After the vehicle has
cleared safe loop outside of property, gate will start to close immediately without opening to limit,
when ON is selected. If second vehicle across loop at this time, gate will stop. The second vehicle
must get off the loop and then gate will continue to close completely.
5. SLAVE: Secondary operator activation
6. OPEB L/R: Choose gate open direction Left or Right.
Features
Figure 17 Dip Switch
DIP Switch Features
There are 6 dip switches located at the bottom of the circuit board. Each switch has a
different feature.