4.4.3. The cooling phase
The screw conveyor is switched off when the cooling phase starts and no wood pel-
lets are conveyed into the burn grate.
4.4.4. Standby mode
Once the set temperature has been reached, the stove switches to the
cooling phase.
When the cooling phase is complete, the standby mode starts. The standby mode
signals that the stove will start heating again automatically when the switch-on tem-
perature is undershot.
4.5. Stove operation with external actuation
The Solida pellet stove offers the pos-
sibility of actuation via an external
thermostat or an external timer. Con-
nection can be implemented on the
rear using the terminal strip next to
the power supply inlet. To connect
the external control system, remove
the cable link (Fig. 6) and connect
the cable of the external control sys-
tem with the RT terminal of the termi-
nal strip.
Fig. 6: Terminal strip with cable link
The pellet stove must be actuated potential-free! Never
apply an input voltage! Only use shielded cables! The
room thermostat may only be connected by a special-
ist!
The external contact must be activated in the control system, simply removing the
cable link is not sufficient.
Activation of the external contact:
Press the button.
Scroll to page K17 with the button.
Activate/deactivate the external contact with the
or
buttons.
Use the button to leave the customer menu and save the
parameters.
The menu is automatically closed and the parameters
saved after 60 seconds.