Platinum Control Center
-- The Control Center can be mounted on a wall or posts.
1. Using the end of the cell cord as a guide, locate a suitable location for the mounting of the Control
Center. The Control Center must be mounted on a noncombustible surface.
2. The wall mounting bracket should be fastened to the wall at a height comfortable for operation.
Screws or anchors are not included. Make sure that the bracket is fastened directly onto concrete with
the proper anchoring device or into a stud in a noncombustible wall surface. Mount the bracket by
installing the one screw, and then leveling the bracket, and installing the other screw, making sure that
the mounting bracket is level and horizontal.
3. If mounting the Control Center on a post, it must be centered on a flat panel of waterproof and non
combustible material at least 10” x 20”. Do not enclose the Control Center in any box.
4. The Platinum Control Center has two mounting bolts installed at the top back of the unit: simply
place the head of the pins in the keyhole slots on the wall bracket, and allow the unit to hang freely.
Your Platinum Control Center is now mounted.
5. Connect 8AWG bonding wire (not included) between the grounding rod and the grounding lug
(located to the left of power cord in illustration above) on the bottom of the Control Center. The
warranty will be voided if the bonding is not correctly done.
Electrolytic Cell
1. Locate pool return line after the heater or filter as shown in the illustration on page 12. This is the
preferred location for the cell housing, but must be located above the highest point of plumbing.
2. Determine height necessary to bring cell above both the heater and the filter inlets and outlets.
3. Cut and glue the risers from the main plumbing into place. Install the cell housing to the top of the
risers, making sure the cell housing is installed level.
4. Install the O-ring into the receiving channel inside the cell housing, and then slide the cell into the cell
housing making sure the key way on the black plastic base aligns with the matching key in the cell housing
(with the water sensor tab in the 12:00 position).
5. Put the main cap into place and hand tighten only; be sure not to strip the threads.
A
C
B
Installation Procedures