California Faucets StyleTherm TH52D2-R Installation Instructions Download Page 3

TH52D2-R_ii_161005 

 

 

 

 

 

 

 

 

 

 

Pg 3 

 

FINISHED WALL 

 

 

VALVE  (1)  shall  be  located  in  framed  wall  so  that 
FINISHED  WALL  (7)  falls  within  the  MIN/MAX 

limits stated on MUDGUARD (4)  

 

The Maximum GAP (8) between FINISHED (7) and 
MUDGUARD (4) shall be no more than 

1

16

” to allow 

for proper trim coverage

 

 

 

These finished wall requirements are necessary for 
proper fit of trim as described in TO-TH1L-XX, TO-
THC1L-XX & TO-THF1L-XX ½ Thermostatic Trim 
with Dual Volume Control Installation Instructions 

 

 

 
 

MAINTENANCE 

Thermostatic Cartridge Service 

 

Shut  off  water  supply  to  thermostatic  cartridge  by 
turning  hot  &  cold  SERVICE  STOP  SCREW  (9) 
clockwise (inward) until screw stops 

 

Remove  CARTRIDGE  NUT  (10)  from  the  BODY 
(1) 

 

Gently pull THERMOSTATIC CARTRIDGE (11) out 
of  BODY  (1)  (rotating  cartridge  while  pulling  may 
assist in removal) 

 

Rinse  cartridge  screens  under  running  water  to 
remove any possible debris 

 

Prior  to  installing  THERMOSTATIC  CARTRIDGE 
(11)  into  BODY  (1),  apply  a  thin  film  of  non-

petroleum based grease onto O-RING (12) 

 

 Align THERMOSTATIC CARTRIDGE STEM (11a) 
indentation  or  ink  line  with  THERMOSTATIC 
CARTRIDGE  GROOVE  (11b)  and  insert 

THERMOSTATIC  CARTRIDGE  (11)  into  BODY 
(1) with THERMOSTATIC CARTRIDGE GROOVE 
(11b) straight up at 12 o’clock position 

 

Tighten CARTRIDGE NUT (10) to 10 ft-lbs 

 

Open  water  supply  to  thermostatic  cartridge  by 
turning  hot  &  cold  SERVICE  STOP  SCREW  (9) 
counter-clockwise (outward) until screw stops 

 
Check Valve Service 

 

Shut off water supply to valve inlets at main or valve 
upstream from BODY (1) 

 

Remove CHECK VALVE (13) from BODY (1) 

 

Rinse CHECK VALVE (13) under running water 

 

Prior to installing CHECK VALVE (13) into BODY 
(1),  apply  a  thin  film  of  non-petroleum  based 
grease onto O-RING (14)  

 

Tighten CHECK VALVE (13) to 10 ft-lbs 

 

1

16

 Gap between 

Mudguard & Finished 

Wall 

WARNING:    Forcibly  rotating 

thermostatic cartridge stem prior to 
installing  handle  trim,  will  damage 

cartridge and void warranty. 

 

5” MAX 

MIN 

Finished 

Wall 

MAX 

Finished 

Wall 

5½” MAX 