California Faucets StyleTherm TH52D2-R Installation Instructions Download Page 1

TH52D2-R_ii_161005 

 

 

 

 

 

 

 

 

 

 

Pg 1 

 

StyleTherm

™ 

 

TH52D2- R 

½” Thermostatic Valve w/ Dual Non-Shared & Single Control Outlets 

Installation Instructions 

 

 

 
 
 

 
 
 

 
 
 

 

 

IMPORTANT:  Read all instructions prior to installation and provide copy of instructions to consumer. 
 
WARNING:
  This valve is factory set to deliver water at 100

°

F; however, it is the installer’s responsibility to verify correct temperature 

setting  to  prevent  risk  on  scalding  or  other  severe  injury  prior  to  consumer  use.    The  installer  is  responsible  for  adjusting  maximum 
temperature setting according to Thermostatic Rough and Thermostatic Trim Installation Instructions. 

 
Operating Specifications: 
 

Recommended Supply Pressure:    

 

  20 to 70 psi

 *†

 

Recommended Hot Water Supply Temperature: 

120 to 140°F 

 

Nominal Flow Rate @ 60 psi (non-shared port): 

7.2 gpm 

Nominal Flow Rate @ 60 psi (lower port):   

10.5 gpm 

 

 
*

 Operating pressures between hot and cold supplies should vary no more than 30 psi. 

 If water pressure exceeds 70 psi, install a Pressure-Reducing Valve (RPV). 

 

Follow all applicable local plumbing codes when setting the temperature on the water heater.

 

 
 

 

 
 
 

CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED 

BY A LICENSED PROFESSIONAL

 

Body 

Dual Non-Shared 

Volume Control 

Thread 

Protector 

Thread 

Protector 

Mudguard 

Mudguard 

Screw 

Mudguard 

Washer 

Valve  

Mounting Tab 

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5

0

10

20

30

40

50

60

70

80

90

100 110 120 130 140 150 160 170 180

F

lo

w

 R

a

te

 (

G

P

M

a

6

0

 p

si

Volume Control Lever Rotation  

(0=full open RT, 90=closed  & 180=full open LT)

Dual non-shared  volume control (upper port)

Single Volume 

Control 

Reviews: