background image

9628SS_ii_170606 

 

 

 

 

Pg 1 

 

9628SS  

for use with California Faucets Hot Water Dispensers ONLY

 

Kitchen Hot Water Dispenser Tank 

Installation Instructions 

 

 

 

 

 

 

 
 
 

 
 
 

 

IMPORTANT:  Read all instructions prior to installation and provide copy of instructions to consumer. 
Operating Specifications: 

Recommended Electrical Supply Outlet Rating:  

120V AC @ 15A Min.

 

 

Recommended Supply Pressure:    

 

20 to 70 psi

 

††

 

 Outlet shall be a 

GROUND-FAULT CURRENT INTERRUPTER (GFCI) type

.

 

††

 If water pressure exceeds 70 psi, install a Pressure-Reducing Valve (RPV).

  

 
 

INSTALLATION OF TANK 

Warning:   

Electrical  outlet  MUST  be  a 

GROUND-FAULT 

CURRENT INTERRUPTER (GFCI)

 type OUTLET 

(13)

 

Important:  

Make sure temperature DIAL 

(6c)

 is turned all the way 

counter  clock-wise  to  the  COLD  position  before  plugging  tank  into 

OUTLET 

(13) 

 

Important:  

There MUST 

be at least a ½” space between 

TANK 

(6) 

and side WALL(S) 

(2)

 for proper air circulation around TANK 

(6)

 

Warning:  

DO NOT store flammable liquids near TANK 

(6)

 

 

 

The  location  of  the  TANK 

(6)

  should  allow  for 

direct installation of the hot water dispenser hoses 
without making loops or kink in the faucet hoses 

 

The surrounding 

WALL(S) 

(2)

 

must be at least a ½” 

to  allow  proper  air  circulation  around  TANK  

(6)

 

 

To prevent TANK 

(6)

 from accidental falling over it 

is recommended to install mounting BRACKET 

(3)

 

to  WALL 

(2)

  and  secure  with  SCREWS 

(4)

  (not 

supplied)  

 

The  use  of  a  shallow  PAN 

(5)

  (not  supplied)  is 

suggested, but not necessary

 

 

 
 

CONNECTIONS TO TANK

 

As  taken  from  California  Faucets  CF-9625-KXX  Kitchen  Hot  Water 
Dispenser Installation Instruction 

 

 

 

Remove  and  discard  from  one  of  the  COUPLING 

(7)

 

one  ¼”  NUT 

(7e)

  &  SLEEVE 

(7d)

 

from  the 

other  COUPLING 

(7)

  remove  &  discard 

one  3/8” 

NUT 

(7c)

 & SLEEVE 

(7b)

 

 

 

Place  ¼”  compression  NUT 

(7e)

  &  SLEEVE 

(7d)

 

onto  hot  tank  INLET 

(6a)

  slide  coupling  BODY

 

(7a)

 on and s

ecurely tighten ¼” compression NUT 

(7e)

 to coupling BODY 

(7a)

  

 

 

Place  3/8”  compression  NUT 

(7c)

  &  SLEEVE 

(7b)

 

onto hot tank OUTLET 

(6b)

 slide coupling BODY 

(7a)

  on  and  securely  tigh

ten  3/8”  compression 

NUT 

(7c)

 to coupling BODY 

(7a)

 

CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING/ELECTRICAL PRODUCTS BE 

INSTALLED BY A LICENSED PROFESSIONAL

 

INLET:  

1/4” 

Comp. 

OUTLET:  

3/8” 

Comp.  

½”

 

 

Discard top  

nuts & sleeves

 

Reviews: