![Calian SatService sat-nms LBRX-1MT User Manual Download Page 20](http://html1.mh-extra.com/html/calian/satservice-sat-nms-lbrx-1mt/satservice-sat-nms-lbrx-1mt_user-manual_3407454020.webp)
interfaces. See chapter '
3 Operation / Remote Control
' for details.
4.2 Processing of Measured Values
The logarithmic detector circuit outputs a dB-proportional voltage to the A/D converter. Hence the measured
ADC samples reflect directly the receiver's input power in dBm. The readings however are subject to vary
by temperature. There is an absolute offset which changes with the temperature, but also the dB to voltage
relation slightly may change.
The beacon receiver software compensates this effect by varying the scale and offset values used to
compute the dBm value from the ADC reading. During the factory tests each beacon receiver gets calibrated
at several temperatures. The data processing of the receiver software then works as described below:
(C) 2020, SatService GmbH
www.satnms.com
LBRX-1MT-UM-2002 Page 19/21