DEFAULT SETTINGS

The PyroNFC is fully configurable via an iOS / Android app. No configuration is necessary: the
sensor will work straight out of the box using the below default settings.

All settings are adjustable except those marked (fixed).

GUARANTEE

Calex guarantees each instrument it manufactures to be free from defect in material
and workmanship under normal use and service for the period of two years from the date
of purchase. This guarantee extends only to the original buyer according to Calex’s standard
Terms and Conditions of Sale.

Setting

Range of Values

Default Value
(PN151)

Default Value
(PN151K)

Output Voltage*

0-5 V / 1-5 V / 0-10 V 0-10 V

Type K
thermocouple (fixed)

Temperature Low*

0°C to 900°C

0°C

0°C (fixed)

Temperature High*

100°C to 1000°C

1000°C

1000°C (fixed)

Alarm Trigger

High / Low / Off

High

High

Alarm Monitor
Temperature

Target / Internal

Target

Target

Alarm Set Point

0°C to 1000°C

30°C

30°C

Alarm Hysteresis

0°C to 30°C

1°C

1°C

Alarm Mode

Active High / Active
Low

Active High

Active High

Alarm Reset

Auto / Manual

Automatic

Automatic

Emissivity Setting

0.2 to 1.0

0.95

0.95

Reflected Energy
Compensation

On/Off

Off

Off

Reflected
Temperature

0°C to 1000°C

25°C

25°C

Averaging Period

0.125 s to 60 s

0.125 s

0.125 s

Hold Mode

Peak/Valley/Off

Off

Off

Hold Period

0.125 s to 120 s

250 ms

250 ms

* These settings are not adjustable on model PN151K.

Calex Electronics Limited

PO Box 2, Leighton Buzzard, Bedfordshire, England LU7 4AZ

Tel: +44 (0)1525 373178 | [email protected] | www.calex.co.uk

Issue E - Apr 2022

8

Summary of Contents for PyroNFC Series

Page 1: ...PyroNFC Series Operator s Guide...

Page 2: ...Adjustable via app Emissivity Setting Range 0 2 to 1 0 Max Temperature Span Linear Output 1000 C Min Temperature Span Linear Output 100 C Spectral Range 8 14 m Max Supply Voltage 28 V DC Min Supply V...

Page 3: ...perate in ambient temperatures from 0 C to 80 C Avoid thermal shock Allow 20 minutes for the unit to adjust to large changes in ambient temperature ATMOSPHERIC QUALITY Smoke fumes or dust can contamin...

Page 4: ...before switching it back on MECHANICAL INSTALLATION All sensors come with a 1 metre cable and two mounting screws The sensor can be mounted on brackets or cut outs of your own design or you can use t...

Page 5: ...urs and Tags 14 0 13 5 31 0 2 x Hole 3 2 Section A A A A 21 5 THIS FACE AGAINST SENSOR AIR OUT Air Inlet Hose barb 5 mm Touch NFC smartphone here Field of view see OPTICS PWR PWR OP 0 V 21 5 31 0 29 0...

Page 6: ...ntinuously while the phone is touching the sensor On iOS the temperature is updated once each time the user taps update in the app The sensor must be powered to read the measured temperature with the...

Page 7: ...can be solved over the telephone If the sensor is not performing as it should try to match the symptom below to the problem If the table does not help call Calex for further advice TROUBLESHOOTING Sym...

Page 8: ...K thermocouple fixed Temperature Low 0 C to 900 C 0 C 0 C fixed Temperature High 100 C to 1000 C 1000 C 1000 C fixed Alarm Trigger High Low Off High High Alarm Monitor Temperature Target Internal Targ...

Reviews: