Calex PyroCAN Series Operator'S Manual Download Page 2

2

PyroCAN infrared temperature sensors measure temperatures from -20°C to 1000°C and transmit 

the reading digitally via a Raw CAN interface. 

SPECIFICATIONS
Temperature Range vs Field-of-View table

Field of View

Model Number

2:1

PCAN21

10:1

PCAN201

Interface 

Raw CAN

Accuracy 

±1% of reading or ±1ºC whichever is greater

Repeatability 

± 0.5% of reading or ± 0.5ºC whichever is greater

Emissivity 

0.2 to 1.0, adjustable via CAN

Response Time, t90 

200 ms (90% response)

Spectral Range 

8 to 14 μm

Supply Voltage 

12 to 24 V DC

Supply Current

 

50 mA max.

Baud Rate 

250 kbps

Format 

see PROTOCOL

 

MECHANICAL

Construction

 

Stainless Steel

Dimensions

 

18 mm diameter x 103 mm long

Thread Mounting

 

M16 x 1 mm pitch

Cable Length

 

1 m

Weight with Cable

 

95 g

ENVIRONMENTAL

Environmental Rating

 IP65

Ambient Temperature

 

0ºC to 90ºC

Relative Humidity

 

95% max. non-condensing

ACCESSORIES

A range of accessories to suit different applications and industrial environments is available. These 

may be ordered at any time and added on-site. The  accessories consist of the following parts .

 

Fixed mounting bracket 

Adjustable mounting bracket 

Air purge collar

  Laser sighting tool 

Protective plastic window with stainless steel holder 

 

Mounting bracket with continuous laser sighting 

OPTIONS

The following options are available. Options are factory installed and must be ordered  with the 

sensor.

 

Air/water cooled housing 

Certificate of calibration 

Longer cable

[email protected]

www.digiparts.ch

Ihr Schweizer Industriepartner

Summary of Contents for PyroCAN Series

Page 1: ...PyroCAN Series Operators Guide info digiparts ch www digiparts ch Ihr Schweizer Industriepartner...

Page 2: ...x 103 mm long Thread Mounting M16 x 1 mm pitch Cable Length 1 m Weight with Cable 95 g ENVIRONMENTAL Environmental Rating IP65 Ambient Temperature 0 C to 90 C Relative Humidity 95 max non condensing A...

Page 3: ...spot diameter at any given distance from the sensing head and assumes 90 energy 1000 103 12 18 M16 x 1mm 11 9 0 Spot Dia inches Spot Dia mm Distance Sensor to object inches Distance Sensor to object...

Page 4: ...AL INTERFERENCE To minimise electromagnetic interference or noise the sensor should be mounted away from motors generators and such like WIRING Check the distance between the sensor and the connected...

Page 5: ...Water flow rate should not be more than 0 5 to 1 5 litres min 40 0 21 19 63 103 M16 x 1mm 1 8 BSP water air connections 1 8 BSP Air connection 25 APSW for PCAN21 50 APSN for PCAN201 20 29 40 AIR PURGE...

Page 6: ...e ID is persistent between power cycles The CAN ID may be set to a value from 0 to 2048 0x0 to 0x800 as a 4 byte unsigned integer The emissivity setting may be set to a value from 0 2 to 1 0 as a 4 by...

Page 7: ...x00 0x00 0x00 Command ID Send the command with these bytes empty The sensor will return the emissivity setting in these bytes as a floating point value After the following commands are sent the sensor...

Page 8: ...lex guarantees each instrument it manufactures to be free from defect in material and workmanship under normal use and service for the period of one year from the date of purchase This guarantee exten...

Reviews: