© Caleffi_20130925_iSolar_WMZ.mon
us.ind
d
| 10
FL
RE
200 l/h
Flow
85,6 °C
45,7 °C
FL
RE
9.30 kW
Power
85,6 °C
45,7 °C
The volumetric flow rate is indicated (l/h or gpm).
The current power is indicated (in kW).
note:
The precision of the power indication depends on the
flowmeter used. At low flow rates, deviations from the
actual value are possible and caused by technical reasons!
6.3 Volumetric flow rate
6.4 Power
All balance values will be reset to 0.
6.5 Reset balance
Adjust. values:
back
Reset balance
Antifr. type
Water
Adjust. values:
back
Antifr. type
Water
Flow measurem.
V40
Adjustment channel for the antifreeze type used. There are
different types of heat tranfer fluid to choose from. Water
or water / glycol mixtures are used:
• water
• propylene
• ethylene
• Tyfo LS
Adjust. values
back
Antifr. type
Propylene
Antifreeze
40 %
Adjustment channel for the ratio of water / glycol (“anti-
freeze“ is only visible, when the antifreeze type “propylene“
or “glycol“ has been selected before).
ajdustment range: 20 % ... 70 vol. %
factory setting: 40 %
Adjust. values:
back
Antifr. type
Water
Flow measurem.
V40
Adjustment channel for the flowmeter type which is used.
The factory setting is V40 flowmeter.
• V40
• VTP
6.6 antifreeze type
6.7 antifreeze
6.8 Type of flowmeter