background image

Calectro AB   Phone: +46 31-69 53 00   [email protected]   www.calectro.com

CMT-24/230V INSTALLATION INSTRUCTIONS

ENGLISH

Universal thermostat with 11 built-in and 
selectable functions. 
Multi-voltage: 24V AC/DC and 230V AC.

WARNING: IMPORTANT
INFORMATION
CONCERNING
ELECTRICAL SAFETY 
AND ENVIRONMENT

The product may incorporate lethal volt-
age. The product's enclosure is not intend-
ed to be opened. At 230V AC supply volt-
age the product shall be powered via a 
proximally mounted disconnection device 
marked: "Disconnection device for ther-
mostat CMT". The product's relay switch 
can be energised with 230V which must 
be disconnected prior to conducting main-
tenance work. The product is intended for 
indoor use. The product shall not be sub-
jected to liquids or moisture. The outside of 
the product can be cleaned using a slightly 
moist cloth rag. The product is intended for 
installation on a DIN rail / Norm enclosure 
in an area protected from the public.

!

INDEX

1.  Technical data

2. Function

3. Use

4. Installation

5. Maintenance

6.  Buttons and menu system

7. 

Selection of application/function

8.  Selection of temperature sensor type - fac-

tory setting: Pt1000

9.  Setting of prefered/ set point values

10.  Setting of hysteresis

11.  Fine-adjustment of the temperature meas-

urement

12.  Setting of timer function

13.  Display example

14.  Error codes and temperature/ohm table

15.  Resetting factory settings

16.   Figures

17. Connection example for each respective 

application

18.  Menu system – overview/quick menu

1.  TECHNICAL DATA

Supply voltage:

 

24V AC ±10%,  

   

24V DC ±5% and 

  

230V AC ±10% 50-60 Hz

Relay outputs:

 

250V ~ 5A resistive  

   

loading, change-over  

  

potential-free

Power consumption:  

4W

Temperature range:  

-99 to +600°C

Ambient temperature: 

0 to +40°C

Selectable  
temp.sensors: 

Pt1000 (factory setting),

 

  

Pt100, Ni1000,

 

  

NTC (Calectro type:  

   

22/33/44/55/99) and

 

  

PTC (Calectro type: 95)

Switching differential: 

0-15°C in stages of 0.2°C

Mounting:

 

DIN rail, Norm-enclosure

Dimensions WxHxD:

  52.5 x 86 x 59mm

Weight:

 

240 g.

Enclosure class:

 IP20

2. FUNCTION

CMT can be powered by 24V AC/DC via plinth 15-16 
or 230V AC via plinth 1-2. See figure 2. CMT has two 
alternating potential-free relay outputs (5 A, 250V) 
and has an adjustable hysteresis (switching differen-
tial) which is centred over the reference value. 

CMT carries out a self-test during start-up and fol-
lowing change of temperature sensor. Three bars 
blink at the lower part of the display. Once the self-
test has finished the actual temperature will be dis-
played. In the case of interruption to the temperature 
sensor the display shows Er0 and in the case of 
short-circuit Er1 is displayed.

3. USE

Universal thermostat with 11 built-in and selectable 
functions:

Appl. 1 

1-stage heating thermostat

Appl. 2 

1-stage cooling thermostat

Appl. 3 

2-stage heating thermostat

Appl. 4 

2-stage cooling thermostat

Appl. 5 

2-stage heating and cooling thermostat

Appl. 6 

1-stage cooling thermostat with low tem-
perature alarm

Appl. 7 

1-stage heating thermostat with overheat-
ing alarm

Appl. 8 

2-stage overheating alarm

Appl. 9 

High and low temperature alarm

Appl. 10  Gutter thermostat, relay 2 = fault alarm
Appl. 11  Gutter thermostat with whole numbers, 

relay 2 = fault alarm

4. INSTALLATION

CMT is mounted on a DIN rail and is adapted to Norm 
enclosures.

Gutter thermostat (application 10 and 11)

Positioning of thermostat and outdoor temperature 
sensor.

In order to counteract icing heated cables are used in 
guttering and downpipes. The temperature at which 
ice forms varies from building to building depending 
on several factors such as, on the degree of insula-
tion, the compass direction, radiated heat from the 
Sun, etc. Position the thermostat in an easily acces-
sible position for service personnel inside the build-
ing. The outside temperature sensor is positioned on 
the building's north elevation in a position away from 
direct sunlight, e.g. under the soffit See figure 3.

5. MAINTENANCE

CMT is maintenance-free.

6.   BUTTONS AND MENU SYSTEM

▲ = Step up in the menu / increase value - Keep 

the button depressed and the reference value 
counts up rapidly.

▼ = Step down in the menu / decrease value - 

Keep  the  button  depressed  and  the  reference 

value counts down rapidly.

 = Is a multi-function button whose current 

function* is shown in the display beside the button.

* Central button functions:

•  Exit Menu = Exit the menu/Save setting
•  Menu Enter = Enter submenu
•  Menu = Enter the menu or select application
•  Enter = Confirm setting 
•  Reset = To reset relay after alarm, applica-

tions 6-9

Menu

Enter

Reset

Exit

The menu system consists of the following sub-
menus:

1.  Selection of temperature sensor
2. Setting of hysteresis
3. Fine-adjustment of the temperature meas-

urement

4. Timer functions
5. End the menu system

7.  SELECTION OF APPLICATION/

FUNCTION

CMT is a multi-functional thermostat with eleven 
selectable applications:

To select an application the central button must 
be in function: "Menu". Press 

 and keep it 

depressed.  Then  press  ▲  and  keep  both  but

-

tons depressed for 4 seconds. APP will now be 
displayed in the upper left-hand corner with the 
relevant application number. On the one side of 
the thermostat there is an application overview. 
Mark the sticker with the application setting for 
future service and maintenance.   Choose the 

desired application with ▲ and ▼ then confirm 

with Enter (

).

Enter



 

© 2021.03.08 R2.0 Calectro 

AB   HFE636 EN

EN

Reviews: