Calculated Industries 098584000554 User Manual Download Page 22

Setting Custom Scales

You can store six Custom Scales: three in 
Imperial Mode and three in Metric Mode. 

You  can  set  a  custom  scale  two  ways:  by 
  rolling in   a known distance or by entering 
the exact distance.

Rolling a Custom Scale

1) Press

[MODE]

 until 

#  OPEN

 (# being 

a number 1-3) appears in the scale box
display.

2) Press 

[SET] [SCALE]

.  

ROLL

   will appear

in the main display.

3)  Roll desired distance.  

ROLLING

   now 

appears in the main display.

4) Press 

[SCALE]

.  The  annunciator  will 

begin  flashing   

FT  IN

    for  Imperial

Mode,

 

M

 

 for Metric Mode.

5) To  change the units of   measurement, 

press

[UNITS]

 until your desired units 

appear. Press the 

[M+]

( ) or the 

[LxW]

( )  key  to  begin  setting  the  distance. 
The selected digit will start flashing.

(cont d)

User s Guide    18

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for 098584000554

Page 1: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...rchitectural and engineering drawings Finds linear measurements of any shape Finds rectangular areas and volumes Converts between scales and dimensions Built in push button counter Subtract function S...

Page 3: ...odes 11 Changing Scales 12 Changing Units 12 Locking Modes Scales and Units 12 Operation 13 Rolling a Measurement 14 Using the Memory Function 15 Additional Memory Functions 16 Programming Mode 17 Set...

Page 4: ...ery Automatic Shut Off 25 Battery Replacement 25 Default Settings 26 Specifications 27 Repair and Return 28 Warranty 29 FCC Class B 30 Looking for New Ideas 30 Contact Us 31 www GlobalTestSupply com F...

Page 5: ...nt values length width count All permanent values and settings such as modes scales and units remain intact Holding down the ON CLEAR key for 2 seconds also powers the unit off ON CLEAR MODE Clear All...

Page 6: ...ramming mode A press of SET after rolling locks the measurement While locked the displayed value will not be affected by rolling the Scale Master Pro A second press of SET will unlock the measurement...

Page 7: ...hanging a setting Setup Keys MODE Mode Selection Repeated presses of MODE will scroll through the available modes See Changing Modes section SUB MODE Scroll Back Modes Holding SUB and repeated presses...

Page 8: ...for custom scales and height Will scroll back through available settings within the preferences M Right Arrow Moves to the right when setting values for custom scales and height Will scroll forward t...

Page 9: ...red length 5 Stored width RCL LxW Length Width Recall Displays the length value Additional presses of LxW will display the width area and volume values On a clear display LxW can be pressed without RC...

Page 10: ...Count Increases the count value by one SUB COUNT Count Subtract Decreases the count value by one RCL COUNT Count Recall Displays the count value in the main display ON CLEAR COUNT Count Clear Clears...

Page 11: ...te the screw located near the wheel tip Rotating the screw about 1 4 to 1 3 turn should be sufficient Rotating the screw within those two values should adjust the wheel between free spinning which is...

Page 12: ...auto count Beep On Button beep on Beep Off Button beep off Rolling Click roll Toggles on or off the clicking sound that occurs while rolling Clic On Rolling click on Clic Off Rolling click off Stored...

Page 13: ...nce to be changed is displayed press the M key to move forward or the LxW key to move backward through the settings for the selected preference 4 Once the desired setting is displayed press the COUNT...

Page 14: ...display Built In Scales Imperial Standard Units Architect Engineer I Engineer II ARCH ENGI ENGII 1 foot 1 inch 1 inch 1 4 10 0 300 0 3 8 20 0 333 3 1 2 30 0 400 0 3 4 40 0 416 6 1 1 1 50 0 500 0 3 2 1...

Page 15: ...0 1 5 1 400 0 1 5 000 1 10 1 500 0 1 6 000 1 20 1 10k 1 25 1 12 5k 1 30 1 20k 1 40 1 25k 1 50k Changing Modes Repeated presses of the MODE key will scroll through the list of available modes Holding S...

Page 16: ...available units Holding SUB when pressing UNITS will scroll backward through the list of available units Locking Modes Scales and Units Your Scale Master Pro comes equipped with a lock switch that pre...

Page 17: ...Operation 13 Scale Master Pro www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 18: ...g The display will register your measurements When you roll the unit be sure to hold the unit upright see the first picture in the Operation section Also make sure you start and stop at the exact poin...

Page 19: ...next value Press M This value is added to your previous value stored in Memory 3 You can continue to add values using the M key Press RCL M to review the total in Memory For count values you must pres...

Page 20: ...ays the total accumulated value in Memory Repeated presses of M will toggle between total accumulated value number of entries in Memory and average value of all entries in Memory ON CLEAR M Clears the...

Page 21: ...ing keys are used in programming mode UNITS Toggles through available units M Advances the cursor to the next place to the right LxW Moves the cursor back to the next place to the left COUNT Increases...

Page 22: ...lay 2 Press SET SCALE ROLL will appear in the main display 3 Roll desired distance ROLLING now appears in the main display 4 Press SCALE The annunciator will begin flashing FT IN for Imperial Mode M f...

Page 23: ...exit the programming mode without saving any value as the Custom Scale Entering a Custom Scale 1 Press MODE until OPEN being a number 1 3 appears in the scale box display 2 Press SET SCALE ROLL will a...

Page 24: ...ode entered scales are direct ratios 6 Press COUNT to increase or RCL to decrease the selected digit Press the M key to move to the next digit to the right or the LxW key to move back to the left 7 On...

Page 25: ...of measurement press UNITS until your desired units appear Press the M or the LxW key to begin setting the distance The selected digit will start flashing 3 Press COUNT to increase or RCL to decrease...

Page 26: ...press LxW to store as Width The main display will show the calculated Area Finding Volume To access Volume after you have your values set for Length Width and Height repeatedly press the LxW key The f...

Page 27: ...eated presses of the LxW key will toggle through additional outputs including Width Area and if Height is stored Height and Volume ON CLEAR LxW Clears the values stored as Length and Width 23 Scale Ma...

Page 28: ...ement the answer will be displayed in the next larger measurement units instead of showing an error for example 10 000 000 MM cannot be displayed so 10 000 M will be displayed instead Interference Exp...

Page 29: ...y to restore power All registers and settings remain intact including all temporary registers Battery Replacement To replace the batteries 1 To remove battery door release snap lock in slot and lift 2...

Page 30: ...1 4 1 50 Custom Scales 1 1 1 1 Linear FT IN MM Area SQ FT SQ M Volume CU YD CU M Length 0 0 0 00 Width 0 0 0 00 Height 0 0 0 00 Count 0 0 Subtract Mode Off Off Preferences Default Button Beep On Rolli...

Page 31: ...R 2032 lithium batteries Approximately 400 hours normal use Display Method Display Capacity Main Display Resolution Accuracy Dimensions 27 Scale Master Pro www GlobalTestSupply com Find Quality Produc...

Page 32: ...product won t turn on check the batteries as outlined in the User s Guide 3 If you need more assistance please go to our website listed below 4 If you believe you need to return your product please ca...

Page 33: ...FROM MISUSE OR ABUSE To obtain warranty service in the U S please go to the website A repaired or replacement product assumes the remaining warranty of the original product or 90 days whichever is lon...

Page 34: ...i cation extension or addition to this warranty Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages so the above limitation...

Reviews: