CHECK CONTROL BOARD
Open access door and view the diagnostic red LED, located on the grey direct spark ignition module.
FAULT CONDITIONS
Error Mode
LED Indication
Internal Control Failure
Steady On
Air Flow Fault
1
flash
Flame with No Call for Heat
2 flashes
Ignition Lock Out
3 flashes
The LED will flash on for ¼
second, then off for ¼
second during a fault condition. The pause between fault
codes is 3-seconds.
INTERNAL CONTROL FAULT
•
If power supply cycles are fluctuating beyond 50/60 cycles such as with an un-stabilized power
supply from a generator, unit will not operate. If the circuit board is faulty the unit will not operate.
AIRFLOW FAULT - LOCK OUT (COMBUSTION AIR FLOW PROBLEMS)
•
Combustion airflow is continually monitored during an ignition sequence by the airflow switch
(PSW). If during the initial call for heat the pressure switch contacts are in the closed position for 30-
seconds without an output to the Combustion Blower, an airflow fault will be declared and the
control will remain in this mode with the combustion blower off.
•
If the airflow switch remains open for more than 30-seconds after the combustion blower output
(L1 & IND) is energized, an airflow fault will be declared and the control will stay in this mode with
the combustion blower off.
•
If the airflow signal is lost while the burner is firing, the control will immediately de-energize the gas
valve and the combustion blower will remain on. If the call for heat remains, the control will wait for
proper airflow to return. If proper airflow air is not detected after 30-seconds an airflow fault signal
will be declared.
Proceed as follows to verify reason for airflow lockout:
1.
Check air intake and exhaust for blockage. Remove any blockage.
2.
Check combustion air blower for dirt. Clean and/or replace as necessary.
3.
If there is no blockage, disconnect fresh air intake at burner head (if equipped). Retry for ignition. If
unit does ignite, check to verify that duct size to unit is of proper size and length and that there is
no blockage. Replace ducting as necessary to reduce amount of air restriction to unit.
4.
If
unit still does not ignite, disconnect exhaust vent at heater and retry for ignition. If unit does ignite,
check to verify that vent size to unit is of proper size and length and that there is no blockage. (Refer
to
on pages 55 to
Error! Bookmark not defined.
). Replace venting as necessary to reduce
amount of restriction.
5.
If after 2, 3 and 4 are performed and unit still does not operate, replace air switch.
6.
Reconnect venting and ducting, verify operation of unit.
Summary of Contents for SR Series
Page 18: ...SR SERIES 14 PIPE BOXES Figure 11 PIPE BOX CONTENT...
Page 19: ...SR SERIES 15 10 3 M REFLECTOR PACKAGE Figure 12 10 3 M REFLECTOR PACKAGE CONTENTS...
Page 20: ...SR SERIES 16 15 4 16 M REFLECTOR PACKAGE Figure 13 15 4 16 M REFLECTOR PACKAGE CONTENTS...
Page 21: ...SR SERIES 17 20 6 1 M REFLECTOR PACKAGE Figure 14 20 6 1 M REFLECTOR PACKAGE CONTENTS...
Page 22: ...SR SERIES 18 30 9 1 M REFLECTOR PACKAGE Figure 15 30 9 1 M REFLECTOR PACKAGE CONTENTS...
Page 23: ...SR SERIES 19 40 12 2 M REFLECTOR PACKAGE Figure 16 40 12 2 M REFLECTOR PACKAGE CONTENTS...
Page 24: ...SR SERIES 20 50 15 2 M REFLECTOR PACKAGE Figure 17 50 15 2 M REFLECTOR PACKAGE CONTENTS...
Page 25: ...SR SERIES 21 60 18 3 M REFLECTOR PACKAGE Figure 18 60 18 3 M REFLECTOR PACKAGE CONTENTS...
Page 26: ...SR SERIES 22 70 21 3 M REFLECTOR PACKAGE Figure 19 70 21 3 M REFLECTOR PACKAGE CONTENTS...
Page 27: ...SR SERIES 23 80 24 4 M REFLECTOR PACKAGE Figure 20 80 24 4 M REFLECTOR PACKAGE CONTENTS...
Page 28: ...SR SERIES 24 10 3 M EXTENSION KIT Figure 21 10 3 M EXTENSION PACKAGE CONTENTS...
Page 29: ...SR SERIES 25 SIDE REFLECTOR PACKAGE Figure 22 SIDE REFLECTOR PACKAGE CONTENTS...
Page 56: ...SR SERIES 52 SIDE REFLECTOR Figure 52 SIDE REFLECTOR INSTALLATION...
Page 78: ...SR SERIES 74 24 0 GAS VALVES Figure 62 GAS VALVE Figure 63 PRESSURE REGULATOR...
Page 94: ...SR SERIES 90...
Page 95: ...SR SERIES 91...