Cal Test Electronics

Safety Summary

To avoid personal injury and/or product damage, review and comply with 
the following safety precautions. These precautions apply to both operating 
and maintenance personnel and must be followed during all phases of 
operation, service, and repair of this probe.

WARNING

 statement calls attention to an operating procedure, 

practice, or condition, which, if not followed correctly, could result 
in injury or death to personnel.

CAUTION

 statement calls attention to an operating procedure, 

practice, or condition, which, if not followed correctly, could result 
in damage to or destruction of parts or the entire product. 

Do Not Work Alone

Do not work alone when working with high voltages.

Inspect the Probe

Inspect the probe and accessories for cracks and frayed or broken leads 
before each use. If defects or damages are noted, DO NOT USE the 
probe.

Dry Conditions

Hands, shoes, floor, and work bench must be dry. Avoid making 

measurements under humidity, dampness, or other environmental 
conditions that might affect safety.

Do Not Remove the Probe’s Casing

Removal of the probe’s casing may expose you to electric shock. If 
necessary, disconnect the inputs and outputs of the probe before opening 
the case.

Hazardous Contact

To avoid injury, remove jewelry such as rings, watches, and other metallic 
objects. Do not touch exposed connections and components when power 
is present.

Unexpected Charges

Hazardous voltages may be present in unexpected locations in circuitry 
being tested when a fault condition in the circuit exists.  

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for CT4196

Page 1: ...A X I N T O 1 M C A T II I D iff e re n ti a l M o d e C o m m o n M o d e D C A C p e a k 3 5 V 1 0 x 3 5 V 1 8 V 5 x 3 5 V 1 x 1 0 x O F F P O W E R O v e r R a n g e 5 x 1 x C T 4 1 9 6 6 0 M H z...

Page 2: ...Inspect the Probe Inspect the probe and accessories for cracks and frayed or broken leads before each use If defects or damages are noted DO NOT USE the probe Dry Conditions Hands shoes floor and wor...

Page 3: ...authorized for use in contact with the human body or for use as a component in a life support device or system Do Not Substitute Parts Do not install substitute parts or perform any unauthorized modi...

Page 4: ...ended operation Compliance and Certifications CE Compliance This product meets the essential requirements of the applicable European Directives as follows z z 2014 30 EU Electromagnetic Directive EMC...

Page 5: ...eing put on the market after August 13 2005 and should not be disposed of as unsorted municipal waste Please utilize your local WEEE collection facilities in the disposition of this product and otherw...

Page 6: ...voltage mains installation POLLUTION addition of foreign matter solid liquid or gaseous ionized gases that may produce a reduction of dielectric strength or surface resistivity POLLUTION DEGREE 2 only...

Page 7: ...5x attenuation setting z z 15 MHz at 1x attenuation setting z z Up to 35 V DC AC peak common mode z z High accuracy 2 z z Power indicator LED z z Over range indicator LED Initial Inspection This unit...

Page 8: ...0 x 3 5 V 1 8 V 5 x 3 5 V 1 x 1 0 x O F F P O W E R O v e r R a n g e 5 x 1 x C T 4 1 9 6 6 0 M H z D i ff e r e n t i a l P r o b e Pincer Clips black and red Alligator Clips black and red Insulated...

Page 9: ...set the attenuation ratio to 5x and for voltages up to 35 V set the attenuation ratio to 10x 4 The power indicator LED should turn on 5 Plug the pincer or alligator clips onto the test leads and conne...

Page 10: ...5x 10x 0 5 V div 5 V div 50 10x 20x 0 5 V div 10 V div Table 1 Oscilloscope Readings Cleaning This probe does not require any particular cleaning If necessary clean the case with a soft cloth WARNING...

Page 11: ...50 dB 1 MHz Maximum Input Voltage 1x DC AC peak 3 5 V Maximum Input Voltage 5x DC AC peak 18 V Maximum Input Voltage 10x DC AC peak 35 V Absolute Maximum Rated Input Voltage each side to ground 600 Vr...

Page 12: ...IEC 61010 1 CAT II Mechanical Characteristics Weight 250 g Dimensions 195 x 55 x 30 mm BNC Cable Length 100 cm Input Leads Length 55 cm each Specifications are subject to change without notice To ens...

Page 13: ...t voltage in common mode is shown as follows 1KHz 1MHz 10MHz 10KHz 100KHz 100MHz Frequency 40 20 30 10 Volgage DC ACpeak CT4196 Maximum Input Voltage Derating Curve 35 25 20 15 Figure 2 CT4196 Deratin...

Page 14: ...sons will not be covered by this warranty Cal Test Electronics reserves the right to discontinue models change specifications price or design of this device at any time without notice and without incu...

Reviews: