background image

2008 Fireplace and Firepit Owner’s Manual 

Page 9

LTR20081006, Rev. A

Installation and Assembly

Natural Gas Conversion

For Both Fireplaces or Fire Pits

CAUTION: This service is to be completed only by an 

authorized  gas  appliance  installer.  Do  not  attempt  this 
conversion on your own as there is risk of serious injury 
or death.

To The Authorized Gas Appliance Installer:

All Cal-Flame Gas Log Fireplaces are shipped from the 

factory equipped to burn on liquid propane fuel. Enclosed 

with this kit is a natural gas conversion kit to allow the 
owner to convert and operate this unit on natural gas. To 

perform this conversion, follow the directions below and 

to the local regulation standards in your area. 

Make sure unit is not in operation and is cool enough 
to  perform  this  service.  Shut  off  and  disconnect 
propane fuel source at the regulator end.

Carefully remove the storage cover, lava rocks and 

fire logs. Turn unit over to access hose connections 

underneath.  

While  holding  the  propane  orifice  in  place  with  a 

wrench,  unscrew  brass  fitting  on  fuel  inlet  hose. 

Unscrew propane orifice and remove. 
Using  the  new  brass  natural  gas  orifice  re-install 

the parts in the same sequence. Turn the protective 
screen  /  air  intake  sleeve  to  allow  a  controlled 

amount of air flow through the screen and into the 

fuel supply tube. Flame should have good retention. 

For a proper burn and as a general rule there should 

be less air flow required and therefore the air intake 

screen  should  be  nearly  closed  when  re-installed. 

This  can  be  adjusted  later  to  create  a  clean  and 

desired flame.  

1.

2.

3.

4.

Refer to photo below for proper placement of parts. 

The  washer  should  insert  next  to  the  protective 

screen cover, then the spring is to be aligned with 

the hole and finally the natural gas orifice is to be 

threaded into the end of the fuel inlet leading into the 

burner. Once tight the other brass fitting connection 

can be made from the fuel line fitted between the 

valve and the orifice.

Connect natural gas supply hose, (not included with 
kit), from supply source. Test for leaks. 

Once the conversion is completed and leak tested, 

reload the fireplace or firepit with the lava rocks and 

fire  logs.  Test  the  unit  while  in  place  and  verify  it 

works properly. If flame from burner is not properly 

adjusted  you  can  adjust  air  intake  by  turning  the 

protective screen cover and air intake sleeve on the 

fuel supply tube.

5.

6.

7.

Applies to the following fireplaces and fire pits:

FRP-1000

FPT-50

FPT-650

FRP-1100

FPT-80

FPT-800

FRP-1500

FPT-90

FPT-900

FRP-2000

FPT-95

FPT-951

FRP-3000

FPT-125

FPT-955

FRP-3100

FPT-600

FPT-1100

FRP-3200

FRP-4300

FRP-4400

Summary of Contents for FPT-1100

Page 1: ...LTR20081006 Rev A 3 10 08...

Page 2: ...installed gas line Certified under American and Canadian national standards Notice to installer These instructions must be conveyed to and remain with the customer Copyright 2008 Lloyds Material Supp...

Page 3: ...s and gasoline Do not block the vents located near the base of your firepit or fireplace as gas may build up in case of leak and cause serious damage Do not install or operate your fireplace in such a...

Page 4: ...his creates a dangerous condition that can result in a fire from behind the valve panel Inspect and clean the burners periodically and follow the guidelines in the maintenance section of this manual T...

Page 5: ...sconnected or not In addition whenever the gas cylinder is connected to the regulator or whenever any part of the gas system is disconnected or replaced perform a leak test As a safety precaution reme...

Page 6: ...t cap in place Enclosures Ensure cylinder valves are always readily accessible A door on the enclosure to gain access to the cylinder valve is acceptable provided it is non locking and can be opened w...

Page 7: ...at surface and restrain it to prevent it from tipping Connection Inspect the hose shipped with the unit for damage Never attempt to use damaged or plugged equipment See your local LP gas dealer for re...

Page 8: ...tural gas comes equipped with its own regulator which MUST NOT be removed If this regulator needs to be replaced use only the type specified by Cal Flame for this appliance Remove the rear panel to ga...

Page 9: ...Place the lava rock around the flat burner plate DO NOT place the lava rock on the burner plate as it will affect the flow of the flame Log placement for FRP 1000 1500 2000 3000 3100 Place the ceramic...

Page 10: ...andling Turn the fire pit on its side Connect the piezoelectric starter and attach the flex hose for the gas supply Place the fire pit back down on its pedestal Attach the gas flex hose to the burner...

Page 11: ...take sleeve to allow a controlled amount of air flow through the screen and into the fuel supply tube Flame should have good retention For a proper burn and as a general rule there should be less air...

Page 12: ...p of the burner FIRST You must have clear and easy access to the ON OFF valve AFTER the appliance is installed and connected to the gas supply in order to safely turn of the burner Make sure the burne...

Page 13: ...with your model If a flame does not start within 10 seconds shut off all gas supply and wait FIVE 5 minutes to allow all gas fumes to clear Re try or go to trouble shooting and start from Step 1 again...

Page 14: ...nobandturncounterclockwise to the ON position To light the burners turn the gas control that regulates gas flow to the burners Turn it from LOW to HIGH to increase the gas flow Close the fireplace scr...

Page 15: ...mpt to burn wood in your appliance without a proper grate installed WARNING Never use liquids such as gasoline or lighter fluid in a wood burning fireplace Serious injury can occur Applies to the FRP...

Page 16: ...re while cleaning the logs as they can become damaged if mishandled Periodically check the hose connecting the LP gas cylinder to ensure it is not cracked or damaged in any way All natural gas hook up...

Page 17: ...0101 Replacement Fire Log Set specify fire pit model when ordering FP0102 Replacement Fire Pit Electronic Igniter FP0103 Replacement Fire Pit Gas Control Knob FP0104 Replacement Fire Pit Propane Fuel...

Page 18: ...7 000 Celtic Milan Campfire Russo Sahara 10 Dia Burner Propane 56 000 Heritage 12 Dia Burner Natural Gas 65 000 Heritage 12 Dia Burner Propane 65 000 Monte Carlo 12 Dia Burner Natural Gas 71 000 Monte...

Page 19: ...e Lack of maintenance Accident Alterations Abuse Neglect The use of components not supplied with the appliance The use of fuel other than those specified Weather including freezing damage long periods...

Page 20: ...__________ Fireplace firepit serial number ___________________________________________________________ Type of fuel circle one Liquid propane Natural gas Date purchased _______________________________...

Reviews: