Cal Flame FPR 4000 Owner'S Manual Download Page 2

CONTACT INFORMATION
If you need additional information and/or assistance, 

contact:
L.M.S. Customer Service Department 

1462 East Ninth Street 

Pomona, CA  91766.
Toll Free: 1-800-CAL-SPAS 

Fax: 1-909-629-3890

WARNING

If the information in this manual is not followed 

exactly, a fire or explosion may result causing 

property  damage,  personal  injury  or  loss  of 

life.

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.
Do  not  store  an  LP  cylinder  not  connected 

for  use  in  the  vicintiy  of  this  or  any  other 

appliance. A fire resulting in serious injury or 

death may occur.

If you are installing a natural gas fireplace, you 

are responsible for ensuring that the natural 

gas line installed is safe to use. Lloyds Material 

Supply (L.M.S.) will not be held responsible 

for an improperly installed gas line.

Copyright 2008 Lloyds Material Supply, Inc. All rights reserved. 

Duplication without written consent is strictly prohibited.
Cal Spas™ and Cal Flame™ are registered trademarks.
Due to continuous improvement programs, all models, operation, 

and/or specifications are subject to change without prior notice.

LTR20081045, Rev. A 

3/1/08

Safety Instructions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1
Installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Leak Testing Procedure .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Location   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Liquid Propane (LP) .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Requirements .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Connection .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Natural Gas .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Requirements .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

High Elevation Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Fireplace Log Set Placement   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Operation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

What To Do If You Smell Gas   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Fireplace Lighting Instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

Appendix  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

Maintenance  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
Replacement Parts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
Fireplace Warranty .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11

Certified under American and Canadian national standards.
Notice to installer: These instructions must be conveyed to 

and remain with the customer.

Summary of Contents for FPR 4000

Page 1: ...LTR20081045 Rev A 3 1 08...

Page 2: ...use Lloyds Material Supply L M S will not be held responsible for an improperly installed gas line Copyright 2008 Lloyds Material Supply Inc All rights reserved Duplication without written consent is...

Page 3: ...s well as solvents cleaning fluids and gasoline Do not block the vents located near the base of your fireplace as gas may build up in case of leak and cause serious damage Do not install or operate yo...

Page 4: ...ve the control compartment burner and circulation air passageways of the appliance be kept clean and free Any guard or other protective device removed for servicing the appliance must be replaced prio...

Page 5: ...precaution remember to always leak test your fireplace outdoors in a well ventilated area Never smoke or permit sources of ignition in the area while doing a leak test Do not use a flame such as a lig...

Page 6: ...Enclosures Ensure cylinder valves are always readily accessible A door on the enclosure to gain access to the cylinder valve is acceptable provided it is non locking and can be opened without the use...

Page 7: ...and restrain it to prevent it from tipping Connection Inspect the hose shipped with the unit for damage Never attempt to use damaged or plugged equipment See your local LP gas technician for repairs A...

Page 8: ...ned shut off valve with easy access Your Cal Flame fireplace for use with natural gas comes equipped with its own regulator which MUST NOT be removed If this regulator needs to be replaced use only th...

Page 9: ...nce Once the fireplace is in position level and safely hooked up to the proper fuel supply install the log grate over the plate burner Place the lava rock around the flat burner plate DO NOT place the...

Page 10: ...he burner FIRST You must have clear and easy access to the ON OFF valve AFTER the appliance is installed and connected to the gas supply in order to safely turn of the burner Make sure the burner is i...

Page 11: ...or gas suppliler Pushinthegascontrolknobandturncounterclockwise to the ON position 1 2 3 4 5 6 7 8 To light the burners turn the gas control that regulates gas flow to the burners Turn it from LOW to...

Page 12: ...ve buildup To clean the logs be sure the fire is out the gas supply is turned off and the logs are cool to the touch The soot can then be brushed of with a dry bristle brush or cloth Take care while c...

Page 13: ...y direct sunlight Damage caused as a result of failure to follow the operating instructions as defined in this owner s manual Misuse Lack of maintenance Accident Alterations Abuse Neglect The use of c...

Page 14: ...d below Fireplace model _______________________________________________________________________ Fireplace serial number _________________________________________________________________ Type of fuel c...

Reviews: