background image

4
4
4
4

5
5
5

6
6
6
6
7

8
8
9

10
10
10

11
11
11

TABLE OF CONTENTS

Introduction

Safety
Technical support
Warranty

Getting started

List of components
Unpacking

Product overview

Description
Operation instructions
Specifications
Mechanical drawing

Free Space alignment

Back-to-back in a single MUX/DEMUX configuration
Back-to-back measurement with a MUX and DEMUX configuration

Crosstalk and coupling efficiency calculation

Calculation of coupling efficiency
Calculation of crosstalk 

Cleaning and maintenance

Cleaning instructions
Troubleshooting

1.

2.

3.

4

5

6.

Summary of Contents for Tilba R

Page 1: ...MITIGATE TURBULENCE WITHOUT ADAPTIVE OPTICS INSTRUCTION MANUAL 2020 11...

Page 2: ......

Page 3: ...scription Operation instructions Specifications Mechanical drawing Free Space alignment Back to back in a single MUX DEMUX configuration Back to back measurement with a MUX and DEMUX configuration Cro...

Page 4: ...optical fiber are laser based and may be hazardous to your eyes Please follow all the necessary safety precautions Warning All statements regarding technical data in this instruction manual are only a...

Page 5: ...ing transport and must be very carefully removed from the transport case 1 First loosen the demultiplexer from the transport case without removing it 2 Next carefully take out the demultiplexer and th...

Page 6: ...mode fibers to the corresponding LC connector 2 Verify the properties of the TILBA R with the alignment procedure The properties should match the performance report Example of intensity profile of Her...

Page 7: ...7 Mechanical drawing...

Page 8: ...ent of insertion losses and the basic functionality of the multiplexer Depending on the material available possible options are Figure 1 with only 1 lens or Figure 2 with two lenses We recommend optio...

Page 9: ...rapidly becomes very sensitive At the best alignment position insertion losses for the fundamental mode should be close to the value on the performance report x2 If a multi channel power meter is avai...

Page 10: ...coupling efficiency for the full MUX DEMUX pair for channel i is equal to i Pi i Pin i Calculation of crosstalk Method for obtaining normalized crosstalk The transmission matrix obtained by the measur...

Page 11: ...and thereby voids the warranty Troubleshooting The TILBA R is a passive device and rarely constitutes a point of failure If you observe an abnormal amount of loss in the systems clean the LC PC conne...

Page 12: ...38 boulevard Albert 1er 35200 Rennes France www cailabs com contact cailabs com CAILabs CAILABS...

Reviews: