2.2 INSTALLATION SITE
Particular care is required in selecting the installation site, as an improper location could
jeopardise the proper operation of the dryer.
This unit is not suitable to be used in explosive atmosphere, where risk of fire could exist, or in
presence of gaseous or solid polluting material.
Don’t use water to extinguish fire on the dryer on in the surrounding area.
Minimal installation requirements :
•
Select a clean room dry, free from dust, and protected from atmospheric disturbances.
•
The supporting plate must be smooth, horizontal and able to hold the weight of the dryer.
•
Minimum ambient temperature 34°F (+1°C), see the data plate for maximum temperature.
•
Allow at list a clearance of 16in (400mm) on each side of the dryer for proper ventilation and to facilitate
eventual maintenance operations.
The dryer doesn't require to be fixed to the supporting surface. Eventual locks will be required for special
installations (on brackets, hanging, etc.).
2.3 INSTALLATION LAYOUT
Suggested dryer installation.
2
1
8
7
9
9
6
OUT
IN
9
4
9
3
5
1
Air compressor
6
Final filter
2
Aftercooler
7
Dryer
3
Condensate separator
8
By-pass group
4
Pre-Filter
9
Condensate drain
5
Compressed air receiver
Summary of Contents for LTE3 HGV
Page 2: ...ENGLISH ...
Page 18: ...FRANÇAIS ...
Page 34: ...ATTACHMENTS ANNEXES F F GB GB ...
Page 36: ...7 2 1 LTE 3 HGV LTE 5 HGV 1 2 3 4 5 6 7 8 9 10 11 14 12 13 16 15 12 ...
Page 37: ...7 2 2 LTE 8 HGV 1 2 3 5 16 6 7 8 9 10 11 14 12 13 15 12 4 ...
Page 38: ...7 3 LTE 3 HGV LTE 8 HGV Air Dryer Controller N COM B D PROBE EVD POWER PR DMC6 PE Vc M M ...