– 3 –
Stor-Dry™ Model 9406
*SAVE THESE INSTRUCTIONS*
The Stor-Dry™ Warm Air Circulator combats mold and mildew by reducing the amount of
moisture available for spores to grow and multiply. This is accomplished using a unique dual
action that utilizes both a low wattage heating element and a fan to circulate air.
NOTE
: The key to keeping any area free of moisture is proper ventilation.
CAUTION!
Surface is hot, avoid contact.
Specifications
9406CAABX
120 Volts, 60 Hz, 0.6A, 70 Watts
9406CA230EUABX
230 Volts, 50Hz, 0.33A, 70 Watts
Care and Maintenance
The Stor-Dry requires very little maintenance. By following the instructions within this manual
the heater will operate problem-free for years.
Unplug unit before cleaning.
A vacuum can be used to clear the heater of any dust build-
up and a dry cloth may be used to wipe the outer surface.
Do not attempt to open the unit to clean.
Operating Instructions
Simply plug the unit into the appropriate outlet. Red LED indicates when unit is operating.
Make sure that airflow is not restricted. The heater has been designed for continuous
operation. Current draw is less than a 100 watt light bulb.
An internal blower pulls cool, damp air in the bottom and releases warm dry air through the
top. Active air circulation technology raises the ambient temperature above the dew point to
control mold and mildew. Designed for low cost continuous use. The amount of water vapour
air can hold (absolute humidity) increases with temperature. The Stor-Dry™ low wattage
heating element slightly warms the room's air to keep the moisture suspended rather than
condensing on surfaces where mold spores can use it to grow. Secondly, the Stor-Dry™ fan
keeps a small amount of air moving throughout the room to help prevent any moisture from
condensing on surfaces to again impede the growth of mold spores.
WARNING
:
This unit is equipped with a thermal protection device.
Should the unit be covered
in clothing or other material it may overheat and shut down. In the event of the unit
overheating and shutting down, it will remain off until it is reset. To reset, unplug the unit
and ensure that it is not covered by anything. Let the unit cool for ten minutes before
plugging it back in.
Summary of Contents for Stor-Dry
Page 2: ... 2 ...
Page 27: ... 27 ...