28
28
English
PROBLEM
POSSIBLE CAUSE
CURE
Milk not dispensed.
• Connection lever
raised.
• Clogged pipe.
• Not connected.
• No milk.
• Lower the connection lever.
• Carry out cleaning.
• Connect it.
• Insert the milk.
The milk does not
reach the set temper-
ature.
Hot milk poured.
Pour cold milk in the milk con-
tainer.
The coffee machine
does not communi-
cate well with the ap-
pliance.
• Data connection cable
disconnected or dam-
aged.
• Appliance disconnect-
ed or in standby mode
• Dirty contacts.
• Check the data connection
cable
Q;
contact the techni-
cian if necessary.
• Insert the plug or press the
button
D
.
• Thoroughly clean the metal
plates inside the container
and the appliance (Fig.12 and
13).
Troubleshooting
The materials and
objects in contact
with food products
comply with the
requirements
of European
Regulation
1935/2004.
Technical data
MISCELLANEOUS
Approx. 13 kg
See the data plate
on the base of the
machine.
MAX 3.7 litres
< 70dB A
240 mm
380 mm
330 mm