INSTALLATION AND SERVICE MANUAL for AVALON
Galleria and Quatro
Servicing Parts
7.2 Shutdown / Storage
Should you need to store this brewing equipment for an extended period of time, follow this procedure to
avoid any risk of injury or damage to the equipment.
1. Turn the unit off and unplug form the power outlet;
2. Drain the hot water tank (see instructions in section 7.1);
3. Empty the soluble canisters and the 3 beans canister;
4. Clean all parts of the unit before storing (see cleaning instructions in section 5)
5. Disconnect the white wire from the heating element (see installation diagram 6.3)
6. Tie down the water level switch’s arm with a “tie-wrap” to keep the float from pulling down on the switch
during transportation. Do not overtighten, this may damage the switch; this is simply to keep the
float from bouncing upand down on the switch.
7.2.1 Storing the brewer assembly
The brewer is the heart of equipment and is responsible for the taste of the cup of coffee. It is therefore
important that you store it properly when it is not in the brewer. Always disengage your brewer clutch
by using a pair of pliers and turning the pin located on the back clockwise until the brew chamber lifts
up. This will release the pressure on the screen and seal. Your brewer must be on its back or its left
side while on a table top. Do not sit the brewer on its right side (wheels and yoke) or straight up as
these positions are not sturdy and could cause it to fall.