Service Software
4.2
Free mode & Multi-cup mode
The electronic key gives acces to free and multi-cup modes. It may only be accessed by the
owner of an appropriate pre-programmed electronic key. The advantage is that the main
door does not need to be opened to activate the SW3 button. The STD mode is temporarily
interrupted from the outside of the coffee brewer.
To access these modes, apply a preprogrammed key on the electronic socket. The following
message should appear on the screen:
To enter the free mode press the «format» button. To enter the multi-cup mode press the
«strength» button. Otherwise, press the «hot water» button to cancel.
If the previous message does not appear on the screen, it means that your key is not
programmed. Programmed electronic keys are essential to access the free and multi-cup
modes. The following procedure allows the programming for a maximum of nine keys. To
enter the configuration menu press the SETUP button (#SW1) on the power board then hit
the «strength» button on the user’s panel. Press «start» until you get to «Program new touch
key», then press «café vanilla» for yes and press «start» to confirm. Apply an electronic key
on the electronic socket. To save this command, press the «hot water» button.
Multi-cup
Choice special mode
Format=Free, STRG=multi