49-10007261 Rev. 0
21
Performance Data Sheet
Model: XWF or XWFE
Ŷ6\VWHPFHUWLILHGE\,$3025 7DJDLQVW16)$16,6WDQGDUGV3IRUWKHUHGXFWLRQRIFODLPVVSHFLILHGRQWKH
performance data sheet and at iapmort.org.
Ŷ$FWXDOSHUIRUPDQFHPD\YDU\ZLWKORFDOZDWHUFRQGLWLRQV
It is essential that the manufacturer’s recommended
installation, maintenance and filter replacement
requirements be carried out for the product to
perform as advertised. See Installation Manual for
Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.89 lpm)
Water Supply
Potable Water
Water Pressure
25-120 psi (172-827 kPa)
Water Temperature
33°F-100°F (0.6°C-38°C)
Capacity
170 gallons (643.5 liters)
Substance Tested for Reduction
Influent challenge
concentration
(mg/L)
Maximum permissible
product water
concentration (mg/L)
Avg %
Reduction
Chlorine Taste and Odor
2.0 mg/L +/- 10%
N/A
96.9
Chloramine Taste and Odor
3.0 mg/L +/- 10%
0.5
96.9
Particulate, Class I
At least 10,000/mL
N/A
91.4
Cysts
50,000/L
N/A
>99.99
Lead
0.15
0.01
98.85
Mercury
0.006
0.002
96.3
Asbestos
107 to 108 fibers/ L
N/A
>99
Toxaphene
0.015 +/- 10%
0.003
86.95
VOC (Chloroform surrogate chemical)
0.300
0.015
99.7
Alachlor
0.050
0.001
> 98
Atrazine
0.100
0.003
> 97
Benzene
0.081
0.001
> 99
Carbofuran
0.190
0.001
> 99
carbon tetrachloride
0.078
0.0018
98
chlorobenzene
0.077
0.001
> 99
chloropicrin
0.015
0.0002
99
2,4-D
0.110
0.0017
98
dibromochloropropane (DBCP)
0.052
0.00002
> 99
o-Dichlorobenzene
0.08
0.001
> 99
p-Dichlorobenzene
0.040
0.001
> 98
1,2-dichloroethane
0.088
0.0048
95
1,1-dichloroethylene
0.083
0.001
> 99
cis-1,2-dichloroethylene
0.170
0.0005
> 99
trans-1,2-dichloroethylene
0.086
0.001
> 99
1,2-dichloropropane
0.080
0.001
> 99
cis-1,3-dichloropropylene
0.079
0.001
> 99
dinoseb
0.170
0.0002
99
Endrin
0.053
0.00059
99
Ethylbenzene
0.088
0.001
> 99
ethylene dibromide (EDB)
0.044
0.00002
> 99
bromochloroacetonitrile
0.022
0.0005
98
dibromoacetonitrile
0.024
0.0006
98
dichloroacetonitrile
0.0096
0.0002
98
trichloroacetonitrile
0.015
0.0003
98
1,1-dichloro-2-propanone
0.0072
0.0001
99
1,1,1-trichloro-2-propanone
0.0082
0.0003
96
heptachlor (H-34, Heptox)
0.025
0.00001
>99
heptachlor epoxide
0.0107
0.0002
98
hexachlorobutadiene
0.044
0.001
> 98
hexachlorocyclopentadiene
0.060
0.000002
> 99
Lindane
0.055
0.00001
> 99
methoxychlor
0.050
0.0001
> 99
pentachlorophenol
0.096
0.001
> 99
simazine
0.120
0.004
> 97
Styrene
0.150
0.0005
> 99
1,1,2,2-tetrachloroethane
0.081
0.001
> 99
Tetrachloroethylene
0.081
0.001
> 99
Toluene
0.078
0.001
> 99
2,4,5-TP (silvex)
0.270
0.0016
99
tribromoacetic acid
0.042
0.001
> 98
1,2,4-Trichlorobenzene
0.160
0.0005
> 99
1,1,1-trichloroethane
0.084
0.0046
95
1,1,2-trichloroethane
0.150
0.0005
> 99
trichloroethylene
0.180
0.0010
> 99
bromoform
0.300
0.015
95
bromodichloromethane
0.300
0.015
95
chlorodibromomethane
0.300
0.015
95
xylenes
0.070
0.001
>99
Meprobamate
400 +/- 20%
60
95.5
Atenolol
200 +/- 20%
30
95.9
Carbamazepine
1400 +/- 20%
200
98.6
DEET
1400 +/- 20%
200
98.6
Metolachlor
1400 +/- 20%
200
98.7
Trimethoprim
140 +/- 20%
20
96.1
Linuron
140 +/- 20%
20
96.6
TCEP
5000 +/- 20%
700
98.1
TCPP
5000 +/- 20%
700
98.1
Phenytoin
200 +/- 20%
30
96
Ibuprofen
400 +/- 20%
60
95.9
Naproxen
140 +/- 20%
20
96.5
Estrone
140 +/- 20%
20
97.1
Bisphenol A
2000 +/- 20%
300
99.1
Nonyl phenol
1400 +/- 20%
200
97.3
PFOA/PFOS
1.5 mg/L +/- 10%
0.07
99.25
NOTE:
While the testing was performed under
standard laboratory conditions, actual performance
may vary.
Replacement Cartridge: XWF or XWFE. For
estimated costs of replacement elements please visit
our website at
gewaterfilters.com
.
WARNING
To reduce the risk
associated with ingestion of
contaminants:
•
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before and after the system.
Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
AVERTISSEMENT
Pour réduire le risque
associé à l'ingestion de
contaminants:
•
N'utilisez pas l'appareil avec de l'eau d'une
qualité incertaine ou non potable sur le plan
microbiologique sans une désinfection en
amont et en aval du système.
Les systèmes
homologués relativement à la réduction d'oocystes
peuvent être utilisés avec de l'eau désinfectée
pouvant contenir des oocystes filtrables.
ADVERTENCIA
A fin de reducir el riesgo
asociado con la ingestión
de contaminantes:
• No se deben usar con agua que no sea
microbiológicamente segura o de calidad
desconocida sin una desinfección adecuada,
antes o después, del sistema.
Los sistemas
certificados para la reducción de quistes se podrían
usar en aguas desinfectadas que puedan contener
quistes filtrables.
PERFORMANCE
DA
T
A
Summary of Contents for CIC36
Page 42: ...18 49 1000721 Rev 0 Notes...
Page 62: ...18 49 1000721 Rev 0 Notes...