background image

31-2000814  Rev. 1

13

Installation

10

  CHECK BURNERS

WARNING

)LUHRU([D]DUG'RQRW

RSHUDWHWKHEXUQHUZLWKRXWDOOEXUQHUSDUWVLQSODFH

A.  

Burners

 - Place surface burners into corresponding 

positions on cooktop.

B.  

Caps

 - Place caps on proper size burner.

C.  

Grates

 - The left and right grates are 

interchangeable. Place the grates on the cooktop.

FINALIZE INSTALLATION

Place the burner grates over the burners. The grates 
should be seated and should not rock.

WHEN ALL HOOKUPS ARE 
COMPLETED

Make sure all controls are left in the off position. Make 

VXUHWKHIORZRIFRPEXVWLRQDQGYHQWLODWLRQDLUWRWKH

range is unobstructed.

Check that all packing materials and tape have been 

UHPRYHG7KLVZLOOLQFOXGHWDSHRQPHWDOSDQHOXQGHU
FRQWURONQREVLIDSSOLFDEOHDGKHVLYHWDSHZLUH
WLHVFDUGERDUGDQGSURWHFWLYHSODVWLF)DLOXUHWR

remove these materials could result in damage to the 
appliance once the appliance has been turned on and 
surfaces have heated.

11

  CHECK SURFACE BURNERS

Push and turn a knob to the LITE position. A clicking 
sound indicates proper operation of the ignition 

V\VWHP:KHQOLJKWLQJDQ\EXUQHUVSDUNVZLOODSSHDU
DWDOOEXUQHUVEXWJDVIORZVIURPRQO\WKHRQHVHOHFWHG
2QFHDLULVSXUJHGIURPWKHVXSSO\OLQHEXUQHUVKRXOG
OLJKWZLWKLQVHFRQGV$IWHUEXUQHUOLJKWVURWDWHWKH

knob out of the LITE position. Try each burner in 
succession until all burners have been checked.

Quality of Flames

Determine the quality of flames visually. Normal 
burner flames should look like (A) or (B).

/RQJEULJKW\HOORZIODPHVDUHQRWQRUPDO1RUPDO
IODPHVPD\VKRZVLJQVRIDQRUDQJHWLQWZKHQZHOO

heated or signs of flickering orange due to particles in 
the gas or air.

(A) Soft blue flames—

Normal for natural gas

(B) Yellow tips on 
outer cones—

Normal for propane (LP) gas

Burner Cap Not Properly Seated

Burner Cap Properly Seated

Summary of Contents for CGY366

Page 1: ...ne LP Gas or Converting Back to Natural Gas From Propane LP 10 Gas Supply 10 Electrical Connections 11 Roll Range into Position 11 Level the Range 12 Replace Oven Door s 12 Check Burners 13 Check Surf...

Page 2: ...RQ Q DQDGD HOHFWULFDO JURXQGLQJ PXVW EH LQ DFFRUGDQFH ZLWK WKH FXUUHQW 6 DQDGLDQ OHFWULFDO RGH 3DUW DQG RU ORFDO FRGHV 6HH Electrical Connections in this section R QRW LQVWDOO WKLV SURGXFW ZLWK DQ DLU...

Page 3: ...D VKHHW RI WKLFN SO ZRRG RU VLPLODU LQVXODWRU LV SODFHG EHWZHHQ WKH UDQJH DQG FDUSHWLQJ For Caf 3DUWV DQG FFHVVRULHV YLVLW RXU ZHEVLWH DW cafeappliances com I RX UHFHLYHG D GDPDJHG UDQJH RX VKRXOG co...

Page 4: ...V in floor under appliance and behind DSSOLDQFH ZDOO As defined in the National Fuel Gas Code ANSI 6 XUUHQW GLWLRQ OHDUDQFHV from non combustible materials are not part of the 16 6 VFRSH DQG DUH QRW F...

Page 5: ...WKH 1DWLRQDO XHO DV RGH 16 6 XUUHQW GLWLRQ OHDUDQFHV IURP QRQ FRPEXVWLEOH PDWHULDOV DUH QRW SDUW RI WKH 16 6 VFRSH DQG DUH QRW FHUWLILHG E 6 OHDUDQFHV OHVV WKDQ PXVW EH DSSURYHG E ORFDO FRGHV DQG RU W...

Page 6: ...LWK WKH NLW MATERIALS PROVIDED Oven Rack Lubricant Runners to protect flooring 3LSH OERZ Anti Tip UDFNHW UDFH DQG 6FUHZV Leveling Leg Wrench Adjustable Wrench ULYHU RU UHQFK Safety Glasses Drill and A...

Page 7: ...H SDFNDJLQJ 5HPRYH VKHOI KROGLQJ EURLOHU SDQ WDSH OLWHUDWXUH SDFNDJH VKHOI lubricant and probe CAUTION RRUV DQG SDVVDJHZD V OHDGLQJ WR WKH installation location require at least 32 opening If the RSHQ...

Page 8: ...SDQHOV SODFH D SDG EHWZHHQ WKH KDQG WUXFN DQG WKH UDQJH 7LOW WKH UDQJH WR ORZHU WKH KDQG WUXFN ZKHHOV RII WKH skid 6 Place the appliance runners on the floor at the left and right sides in front of th...

Page 9: ...I WKH UDQJH LQ WKH UHFHVVHG DUHD QVWDOO KH VFUHZV SURYLGHG through the brace and into the range NOTE This anti tip device may be installed on the opposite side of the range 0HDVXUH DQG PDUN LPHQVLRQ V...

Page 10: ...SLSLQJ UHVWULFWV PRYHPHQW RI WKH UDQJH WKH XVH RI D 6 QWHUQDWLRQDO FHUWLILHG IOH LEOH PHWDO appliance connector is recommended unless local codes require a hard piped connection I WKH KDUG SLSLQJ PHW...

Page 11: ...LW LV WKH SHUVRQDO UHVSRQVLELOLW DQG REOLJDWLRQ RI WKH FXVWRPHU WR KDYH LW UHSODFHG ZLWK D SURSHUO JURXQGHG WKUHH SURQJ ZDOO UHFHSWDFOH 2 127 81 5 1 5 8067 1 6 87 25 REMOVE THE THIRD GROUND PRONG FROM...

Page 12: ...WUDFW WKH OHJV DQG DOORZ WKH UDQJH WR UHVW RQ LWV UROOHUV H VXUH WR UHWXUQ WKH ZUHQFK WR LWV VWRUDJH VORW IRU future use 8 LEVEL THE RANGE cont REAR LEG ADJUSTMENT WARNING To reduce the risk of fire o...

Page 13: ...VWLF DLOXUH WR remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated 11 CHECK SURFACE BURNERS Push and turn a knob to the LITE p...

Page 14: ...ge RRVHQ WKH WZR VFUHZV RQ HDFK HQG GMXVW WKH WRHNLFN KHLJKW E VOLGLQJ WKH XSSHU DQG ORZHU SLHFHV DSDUW WR OHVV WKDQ WKH PHDVXUHG KHLJKW 6HFXUH WKH WRS DQG ERWWRP VHFWLRQV E WLJKWHQLQJ WKH VFUHZV RQ H...

Page 15: ...G WKH range hood according to the installation instructions 5HPRYH WKH EDFNVSODVK SDFNDJLQJ DQG SURWHFWLYH film 8VH D OHYHO WR SHQFLO D KRUL RQWDO OLQH RQ WKH ZDOO DERYH WKH UDQJH RU UDQJHWRS 7KH JDS...

Page 16: ...EHWZHHQ WKH ERWWRP RI WKH KRRG DQG WKH WRS RI the range The vent hood should be installed over the rangetop or range before installing this backsplash QVWDOO DQG OHYHO WKH 5DQJH 5DQJHWRS DFFRUGLQJ WR...

Page 17: ...ide access is blocked QVWDOO ERWWRP FRYHU RYHU WKH ERWWRP VXSSRUW ZKLOH GULYLQJ RQH VFUHZ LQWR HDFK VLGH ROG WRS FRYHU LQ SODFH ZKLOH PDUNLQJ VFUHZ ORFDWLRQV MXVW EHORZ VKHOI VXSSRUW DQG RQWR ERWWRP F...

Page 18: ...VWDOODWLRQV GHVFULEHG LQ WKLV ERRN VDIHW JODVVHV RU JRJJOHV VKRXOG EH ZRUQ NOTE Product improvement is a continuing endeavor at SSOLDQFHV 7KHUHIRUH PDWHULDOV DSSHDUDQFH DQG VSHFLILFDWLRQV DUH VXEMHFW...