Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
EASY3000/4000 Embedded Assembly SYstem
01/09/2005
5
NPO:
Filename:
Number of pages:
Page:
00105/03:A1676A.MUTx/05 A1676A_REV5.DOC 27
18
Table 3.1 – EASY 3000 crate connections second issue
Name Description
J1,J2
48V SERVICE connectors (in parallel); input of 48 V supply for auxiliary low
voltages in boards
J3..6
48V POWER connectors (in parallel); input of 48 V supply for DC/DC
converters
F2
100 Amps fuse on 48 V POWER line
Com1..4
I/O of EASY bus for remote control
48V power/service
status
1
:
Connectors for inputs from 48V supplies. Through this input the remote
EASY board microcontroller can detect failures in supply voltages and
consequently enables PS channels ramping down, while service supply
voltage is provided by a back up battery
FAN_CTR
Control link for fan unit (Mod. A3000F)
EARTH
Earth link for the crate
3.2.2
EASY 3000 crate panel first issue
Fig. 3.2 – EASY 3000 crate panel first issue
1
This feature is not yet implemented
OUTPUT
INPUT
COM2
COM1
COM3
48V STATUS
EARTH
EASY BUS
48V Service
48V Power
- +
- +
-
-
+
+
J3
J1
J2
L2
F1
F2
J4
L1
L4
J6
J5
L3
CO
M1
COM2
48V
STATUS
EARTH
COM3