User's Manual (MUT)
A3484-A3485 AC/DC Converter 400 V 3-phase 48 V 2.5/5kW
04/07/2017
3
NPO:
Filename:
Number of pages:
Page:
00120/04:A348x.MUTx/03
A3485_REV3.DOC
21
18
A read access to the
12VPwS#CoClose
item returns back the label “On” associated to
12VPwS=OK.
A read access to the
StatusIn
item returns the StatusIn connector signal.
A read access to the
StatusIn#CoOpen
item returns back the lab
el “Off” associated to
StatusIn = FAIL.
A read access to the
StatusIn#CoClose
item returns back the label “On” associated to
StatusIn = OK.
A read access to the
Sync
item returns the external 50 Hz status.
A read access to the
Sync#CoOpen
item returns back
the label “Off” associated to
Sync=FAIL.
A read access to the
Sync#CoClose
item returns back the label “On” associated to
Sync=OK.
A read access to the
HVSync
item returns the external 625 Hz status.
A read access to the
HVSync#CoOpen
item returns back th
e label “Off” associated to
HVSync=FAIL.
A read access to the
HVSync#CoClose
item returns back the label “On” associated to
HVSync=OK.
A read access to the
RemBdName
item returns a string with the board name.
Table 4.4 – Internal Channel items
ItemID
Data Type
Access
Description
PowerSupplyName.BoardXX.ChanYYY.Name
String
R/W
Channel name
PowerSupplyName.BoardXX.Chan0.SerNum
2-byte int.
R
Board serial number
PowerSupplyName.BoardXX.Chan0.Rel
String
R
Board firmware release
PowerSupplyName.BoardXX.Chan0.12VPwS
boolean
R
12VPS status
PowerSupplyName.BoardXX.Chan0.12VPwS#CoOpen
string
R
12VPS open label
PowerSupplyName.BoardXX.Chan0.12VPwS#CoClose
string
R
12VPS close label
PowerSupplyName.BoardXX.Chan0.StatusIn
boolean
R
StatusIn status
PowerSupplyName.BoardXX.Chan0.StatusIn#CoOpen
string
R
StatusIn open label
PowerSupplyName.BoardXX.Chan0.StatusIn#CoClose
string
R
StatusIn close label
PowerSupplyName.BoardXX.Chan0.Sync
boolean
R
Sync status
PowerSupplyName.BoardXX.Chan0.Sync#CoOpen
string
R
Sync open label
PowerSupplyName.BoardXX.Chan0.Sync#CoClose
string
R
Sync close label
PowerSupplyName.BoardXX.Chan0.HVSync
boolean
R
HVSync status
PowerSupplyName.BoardXX.Chan0.HVSync#CoOpen
string
R
HVSync open label
PowerSupplyName.BoardXX.Chan0.HVSync#CoClose
string
R
HVSync close label
PowerSupplyName.BoardXX.Chan0.RemBdName
string
R
Board name
4.1.2
Output Channel OPC Items
This chapter describes the items which are available for the control of the power supply
channels.
The
Name
item allows to assign to the channel a symbolic name.
The
V0set
item allows to set V0.
A read access to the
V0set#EU
item returns a string with the V0set Engineering Units.