4. Operating modes
The Mod. A3484S/A3485S can be controlled, either locally or remotely, through the
SY 1527 software interface.
For details on the EASY3000 System, please refer to the User's Manual of the A1676A
Branch Controller. For details on SY 1527 system operation, please refer to the User's
Manual of this product.
ATTENTION
THE MOD. A1676A and A348x BOARDS REQUIRE
SY 1527 FIRMWARE VERSION 2.01.00 OR LATER
4.1
Output control and monitoring
The control software handles two types of channels: the
Channel 0
, which is a “virtual”
internal channel and it is used to manage the board parameters, and the
Channnel 1
and
2
(A3484S has Channel 1 only), which are the actual output channels. A1676A Branch
Controller parameters are listed in the relevant User's Manual.
Table 4.1 – CH0 Parameters (Board parameters)
Name
Dir
Sign
ValType
Min
Max
Res
UM
OnStr
OffStr
Name
SET
UNSIGNED
STRING
Rel
MON UNSIGNED
NUMERIC
1.00
99.99
0.01
NONE
12VPwS
MON UNSIGNED
ON_OFF
Fail
Ok
Sync
MON UNSIGNED
ON_OFF
Fail
Ok
HVSync
MON UNSIGNED
ON_OFF
Fail
Ok
StatusIn
MON UNSIGNED
ON_OFF
Fail
Ok
SerNum
MON UNSIGNED
NUMERIC
1
65535 1
NONE
RemBdName
MON UNSIGNED
ON_OFF
A348x
A348x
Name
allows to assign a symbolic name to the board
Rel
allows to readout the module firmware release.
12VPwS
allows to readout the status of the +/-12V voltages generated
inside the module.
If
12VPwS = Fail
all channels are turned OFF.
Sync
allows to readout the status of the 50Hz synchronisation signal
(EASY BUS) provided by the A1676A Branch Controller .
If
Sync = Fail
all channels are turned OFF.
HVSync
allows to readout the status of the 625KHz EASY BUS clock
signal provided by the A1676A