2.  Safety information and installation requirements 

 

2.1 

General safety information 

 
This  section contains the fundamental safety rules for the installation and operation of the 
boards. Read thoroughly  this section before starting any procedure of installation or 
operation  of the product. 

2.1.1 

Injury Precautions 

 
Review the following precautions to avoid injury and prevent damage to this product or 
any products connected to it. To avoid potential hazards, use the product only as 
specified. Only qualified  personnel should perform  service procedures. 

 

Avoid Electric Overload. 

To avoid electric shock or fire hazard, do not apply a voltage to a load that is outside the 
range specified for that load. 
 

Avoid Electric Shock.

 

To avoid injury or loss of life, do not connect or disconnect cables while they are 
connected to a voltage  source. 
 

Do Not Operate Without Covers.

 

To avoid electric shock or fire hazard, do not operate this product with covers or panels 
removed. 
 

Do Not Operate in Wet/Damp Conditions. 

To avoid  electric shock, do not operate  this product in wet or damp conditions. 
 

Do Not Operate in an Explosive Atmosphere. 

To avoid  injury or fire hazard, do not operate this product in an explosive atmosphere.

 

 
Do Not Operate With Suspected Failures.

 

If you suspect there is damage to this product, have it inspected by qualified service 
personnel. 

2.2 

Safety Terms and Symbols on the Product 

 
These  terms may appear  on the product: 
 

 

DANGER

  indicates an injury hazard immediately accessible as you read the 

marking. 

 

WARNING

  indicates an injury hazard not immediately accessible as you read the 

marking. 

Summary of Contents for A 1735

Page 1: ...Technical Information Manual MOD A 1735 A 1835 A 1735B A 1835B 12 28 CHANNEL HV BOARDS MANUAL REV 8 24 March 2014 Revision n 8 NPO 00101 00 17XXx MUTx 08...

Page 2: ...ight to change partially or entirely the contents of this Manual at any time and without giving any notice Disposal of the Product The product must never be dumped in the Municipal Waste Please check...

Page 3: ...ON 5 1 2 CHANNEL CHARACTERISTICS TABLE 6 1 3 FRONT PANEL 7 1 4 TECHNICAL SPECIFICATIONS 8 1 4 1 Packaging 8 1 4 2 External connections 8 1 4 3 Displays 9 1 4 4 Other components 9 2 SAFETY INFORMATION...

Page 4: ...5B A1835B_REV8 DOCX 14 4 LIST OF FIGURES FIG 1 1 MOD A 1735 A 1835 LEFT AND MOD A 1735B A 1835B RIGHT FRONT PANEL 7 FIG 1 2 MOD A 1735B A 1835B HVMULTIPIN CONNECTOR 9 FIG 3 1 A MOD A1735 A 1835 SIDE V...

Page 5: ...DOWN rates may be selected independently for each channel in the range 1 500 V s in 1 V s steps The output current is monitored with 20 nA 500 nA resolution depending on current range if a channel tri...

Page 6: ...nA depending on current range Mod A 1835 A 1835B VMAX hardware 0 1 5 kV common for all the board channels VMAX hardware accuracy 2 of FSR VMAX software 0 1 5 kV settable for each channel VMAX softwar...

Page 7: ...T P U T S SCALER POSITIVE 12 CH Mod V560E Mod A 1835P HV EN input connector Channel output connector Channel LED SCALER Mod V560E Mod A1835BP 28 CH HV EN MAXV GND GND GND GND GND NC NC NC NC NC 6 NC...

Page 8: ...35 A 1835 Mechanical specifications HV coaxial connectors Radiall SHVR317580 type Electrical specifications high voltage output according to specifications given in Table 2 1 p 6 CH 0 27 A 1735B A 183...

Page 9: ...positive polarity version yellow LEDs for negative polarity version HV ON LED A 1735B A1835B Function it lights up if at least one output channel is on Type red LED for positive polarity version yell...

Page 10: ...ck or fire hazard do not apply a voltage to a load that is outside the range specified for that load Avoid Electric Shock To avoid injury or loss of life do not connect or disconnect cables while they...

Page 11: ...product The following symbols may appear on the product DANGER ATTENTION High Voltage Refer to Manual 2 3 Installation The Mod A 1735 A 1835 are single width boards which can be inserted in any slot...

Page 12: ...tput channel it is possible through the SYX527 system to perform the following operations Assign to channel a symbolic name Set output voltage VSET Set max output current ISET Set output voltage softw...

Page 13: ...o enable the board s operation Provide the HV EN connector with a 50 Ohm termination Provide short circuit between Pin 51 and Pin 52 IINT and IEXT of the HV Multipin Connector see Fig 2 2 this is a sa...

Page 14: ...els Dip Switch side view T A B C 4 3 2 1 A B Dip Switch T A B C 4 3 2 1 Channels Channels Channels Channels Channels Channels Channels Fig 3 1 A Mod A1735 A 1835 side view B Mod A1735B A 1835B top vie...