- Quattro Technical Information Manual
54
7
CUSTOM PROFILE
Introduction
The use of the
CUSTOM profile allows the user to upload his own scripts to the reader.
The connection to the Quattro Reader using the CUSTOM profile is possible only via the Ethernet port.
If your reader is in EASY2READ or HID profile active, in order to set the CUSTOM profile please refer to the
Warning:
Note that, when configured in the CUSTOM profile, the Quattro R4321P reader
cannot be controlled using the
CAEN RFID Easy Controller Application
.
Set the CUSTOM profile
If your reader is in EASY2READ or HID profile active, in order to set the CUSTOM profile, access the web
interface that is possible only via the Ethernet connection:
1.
Connect the Quattro to the power supply.
2.
Plug an Ethernet cable
11
(not provided) into your computer and connect the other end of the Ethernet
cable to the reader. If your private network matches the default network configuration of the reader
(IP address 192.168.0.2) you can connect to it, otherwise you can:
a.
change the network configuration of the reader (see §
page 19) to connect it to your
network
or
b.
disconnect your PC from your network and connect it to the network of the reader.
By factory default, the Quattro web interface is reachable at the following IP address: 192.168.0.2.
To login, type
root
in the Username text box and
root
in the Password textbox. To change the username
and password please refer to
11
For proper operation of the device:
-
Ethernet cable shall be CAT6 at least (type S/FTP or S/STP)
-
Put two ferrites (P.N. RRC-13-7-23-M-K5B by RICHCO; CAEN RFID ordering code LFAAFFP00004) on the Ethernet cable,
near the reader connector.