Quattro Technical Information Manual
37
5
EASY2READ PROFILE
Introduction
By default, the reader profile is set to EASY2READ. If your reader is in HID or CUSTOM profile active, in
order to set the EASY2READ profile please refer to the next paragraph §
With the EASY2READ profile active you will use the CAEN RFID easy2read communication protocol and the
reader can be controlled using the
CAEN RFID Easy Controller Application
library.
The connection to the Quattro Reader using the EASY2READ profile is possible via the Ethernet port or the
USB port.
Set the EASY2READ profile
If your reader is in HID or CUSTOM profile active, in order to set the EASY2READ profile, access the web
interface that is possible only via the Ethernet connection:
1.
Connect the Quattro to the power supply.
2.
Plug an Ethernet cable
7
(not provided) into your computer and connect the other end of the Ethernet
cable to the reader. If your private network matches the default network configuration of the reader
(IP address 192.168.0.2) you can connect to it, otherwise you can:
a.
change the network configuration of the reader (see §
page 19) to connect it to your
network
or
b.
disconnect your PC from your network and connect it to the network of the reader.
By factory default, the Quattro web interface is reachable at the following IP address: 192.168.0.2.
To login, type
root
in the Username text box and
root
in the Password textbox. To change the username
and password please refer to
7
For proper operation of the device:
-
Ethernet cable shall be CAT6 at least (type S/FTP or S/STP)
-
Put two ferrites (P.N. RRC-13-7-23-M-K5B by RICHCO; CAEN RFID ordering code LFAAFFP00004) on the Ethernet cable,
near the reader connector.