background image

P.2

Installation Instructions

How do I install for

new construction?

Figure 1

Face of wall can must extend

1

/

2

inch or 

5

/

8

inch from face of

stud to allow for thickness of
sheetrock.

The CB Series heater REQUIRES A MINIMUM distance
of 6 inches from adjacent surfaces and 4

1

/

2

inches from

the floor.  However, Cadet RECOMMENDS 12 inches
from all adjacent surfaces and 12 inches above the floor
for longer and cleaner performance.  Heaters must be
spaced at least 3 feet apart.

Secure the wall can to the stud with 2 screws (See
Figures 1 & 2). As an option, the rubber shim provided
may be attached to side of wall can to square the wall
can to the stud.

STEP 1

Mount The Wall Can

How do I install in

an existing wall?

Cut a hole 8 inches wide by 10

1

/

4

inches high next to a

wall stud. This heater REQUIRES A MINIMUM distance
of 6 inches from adjacent wall surface and 4

1

/

2

inches

from the floor. However, Cadet RECOMMENDS 12 inches
from all adjacent wall surfaces and 12 inches from the
floor (See Figure 4).

STEP 1

Cut Hole In Wall 

Route the supply wire from circuit breaker to heater.
Remove a knockout and attach the supply wire with a
strain relief connector, leaving 10 inches wire lead for
later use. Connect supply ground wire to grounding
pigtail in wall can (See Figure 3). Proceed to PART
TWO.

STEP 2

Connect Supply Wires

Figure 2

Attach wall can to stud with
screws through holes provided
in wall can.

Figure 3

Figure 4
Model CB

READ ALL

INSTRUCTIONS

AND SAFETY

INFORMATION

IMPORTANT!

It is extremely

important you verify

that the electrical

supply wires are the

same voltage as the

heater (240 volt

heater to 240 volt

power supply). If

replacing an existing

heater, check the

labels of the old

heater and replace

using the same

voltage. Hooking a

240 volt heater to a

120 volt power supply

will drastically

reduce the heater's

output. Hooking a 120

volt heater to a 240

volt power supply

will destroy the

heater.

Connecting  your

heater to an

incompatible power

supply will void the

warranty.

Part One

PLACEMENT:

Install the Com-Pak Bath Heater (Model CB) vertically. Heater is not approved for horizontal or ceiling

mount applications. 

CONTROLS:

A built-in single pole thermostat and 60 minute timer. (Note: Do not use with a wall thermostat).

Route supply wire from circuit breaker directly to heater.
Remove a knockout and attach the supply wire with a
strain relief connector, leaving 10 inches wire lead for
later use (See Figure 3). Connect supply ground wire to
grounding pigtail supplied in wall can.

STEP 2

Connect Supply Wires

Insert wall can into opening; keeping wall can flush with
wall surface. Secure can to wall stud with 2 screws
through holes provided in can. 

Proceed to PART TWO

Mount The Wall Can

STEP 3

Proceed to Part Two

Summary of Contents for The Com-Pak CB132T

Page 1: ...y ground wire 5 If you need to install a new circuit or need additional wiring information consult a qualified electrician 6 Protect electrical supply from kinks sharp objects oil grease hot surfaces...

Page 2: ...gure 3 Proceed to PART TWO STEP 2 Connect Supply Wires Figure 2 Attach wall can to stud with screws through holes provided in wall can Figure 3 Figure 4 Model CB READ ALL INSTRUCTIONS AND SAFETY INFOR...

Page 3: ...hermostat all the way up and wait approximately 30 seconds 120 seconds for some electronic thermostats If the heater turns on you have turned off the wrong circuit breaker at the electrical panel boar...

Page 4: ...ed the manual high temperature reset switch 3 Heater has tripped the secondary over temperature switch 4 Power not on at the circuit breaker 5 Broken or poorly connected wire s to heater 6 Defective t...

Page 5: ...cesita informaci n adicional sobre el cableado consulte a un electricista calificado 6 Evite que los cables de suministro el ctrico se retuerzan o entren en contacto con objetos afilados aceite grasa...

Page 6: ...ables de suministro gu a Figura 2 Conecte la c mara de pared al puntal mediante los tornillos por los orificios que contiene la c mara Figura 3 Figura 4 MODELO CB LEA TODAS LAS INSTRUCCIONES E INFORMA...

Page 7: ...el c modo gire la perilla del termostato en sentido contrario a las manecillas del reloj hasta que el calentador se apague El calentador se encender y apagar autom ticamente seg n esta temperatura pre...

Page 8: ...be reemplazarse el calentador o el ventilador 2 Quite la obstrucci n y oprima el bot n de reglaje del calentador despu s de dejar que la unidad se enfr e Pruebe el funcionamiento del calentador si el...