INSTALLATION INSTRUCTIONS

      KNOCK-OUT

   (TWIST TO

REMOVE)

      KNOCK-OUT

   (TWIST TO

REMOVE)

STRAIN RELIEF

CONNECTOR

SUPPLY

WIRE

Agujero ciego

(gire para

  quitarlo)

Conector de

atenuacion de 

tension

Cable de

suministro

PLACEMENT: For best results install the NLW heater on an inside wall. Headers and bracing are not necessary. 

NOTE: The wall can must be installed in the TOP UP (vertical) position only. Heater is not approved for ceiling mount.

THERMOSTAT: A built-in double pole thermostat is included.

REQUIRED MINIMUM distance of 6 inches from adjacent surfac-

es and 6 inches from the floor (See Figure 3). However, Cadet 

RECOMMENDS 12 inches from adjacent surfaces and floor for 

longer and cleaner performance. The maximum distance from the 

floor to the bottom of the heater is 24 inches. Heaters must be 

spaced at least 3 feet apart.  
Secure the wall can to the studs with screws through the larger 

(3/16 inch) holes. (See Figures 1 and 2).

Cut a hole 14 1/4 inches wide by 19 1/4 inches high next to a wall 

stud.  REQUIRED MINIMUM distance of 6 inches from adjacent 

surfaces and 6 inches from the floor (See Figure 3). However, Ca

-

det RECOMMENDS 12 inches from adjacent surfaces and floor 

for longer and cleaner performance. The maximum distance from 

the floor to the bottom of the heater is 24 inches. Heaters must be 

spaced at least 3 feet apart.

Figure 4

Figure 3

Figure 2

Figure 1

Face of wall can must extend 

1/2 inch or 5/8 inch from face 

of stud to allow for thickness of 

sheetrock. Mount wall can flush 

with finished surface.

STEP 2

 

Route Supply Wires

Route supply wire 

from circuit breaker to 

top of wall can. Re-

move knockout and 

attach the supply wire 

with a strain relief 

connector, leaving 6 

inches of wire lead 

for later use. Connect 

supply ground wire to 

grounding screw in 

wall can (See Figure 

4).

__________________________

     

 

Part One

      

__________________________

How do I install for new construction?

STEP 1

 

Mount The Wall Can

How do I install in an existing wall?

STEP 1

 

Cut A Hole In The Wall

SUPPLY

GROUNDING

WIRE

TOP

VIEW

GROUNDING

SCREW

VISTA

PRIMERA

TORNILLO

DE PUESTA

A TIERRA

CABLE DE PUESTA 

A TIERRA DEL

SUMINISTRO

Page 3

1.   All electrical work and materials must comply with 

the National Electric Code (NEC), the Occupational 

Safety and Health Act (OSHA), and all state and local 

codes.

2.   Use copper conductors only.
3.   DO NOT install the heater directly above bathtub 

or sink. DO NOT install in shower stall area. Cadet 

recommends installing your heater at least 2 feet (61 

cm) away to prevent contact with water.

4.   Heater must be connected  to a GFCI protected 

branch circuit when installed in a bathroom.

5.   Heater must be installed in a wall can:
    Model NLW - wall can models NLWC or NLWC-S 

6. 

  DO NOT install the heater in a floor, below a towel 

bar, behind a door, or anywhere the air discharge 

may be blocked in any manner.

7. 

   To reduce the risk of fire, do not store or use gasoline 

or other flammable vapors and liquids in the vicinity 

of the heater.

8.    Connect grounding lead to grounding screw provid-

ed. Keep all foreign objects out of heater.

9.    Electric heaters must be installed on a circuit 

dedicated to electric heaters, they cannot share a 

circuit with outlets, lights, or other appliances.