INSTALLATION INSTRUCTIONS

5

CEILING MOUNT

11

10

9

1

2

3

12

5

8

7

6

4

13

Figure 5

Parts Package

wall 

mount

ceiling 

mount

Ceiling Mount

Figure 6

Figure 8

Figure 7

screw

screw

screw

ceiling rafters

½" 

plywood

1. Securely fasten a piece of plywood (not provided) across two of your ceiling rafters that is a 

minimum of ½ inch thick, 8 inches wide and long enough to span the distance across the two 

rafters (See Figure 6). Note: A 240 volt receptacle must be within six feet of the heater. 

2. Remove stand from heater by loosening knobs on each side.
3. Attach the stand to the plywood with the three 2 inch screws provided through the three small 

holes indicated (See Figures 5, 6 and 7).

4. Place heater on stand and tighten knobs. Tilt top of heater down approximately 30 to 45 degrees 

toward your work area (See Figure 8).

5. Proceed to OPERATING INSTRUCTIONS. 

Summary of Contents for Hot One

Page 1: ...ADET US Vancouver Washington USA A S SEMBLED I N tested to UL standards Thank you for your purchase Question or problem Let us solve it with a single phone call email or online chat We ll save you a t...

Page 2: ...cord with throw rugs runners or similar coverings Arrange cord away from traffic area and where it will not be tripped over 9 To disconnect heater turn controls to off then remove plug from receptacl...

Page 3: ...s for use with 240 volts The cord has a 20 amp or 30 amp plug as shown in Figure 1 No adapter is available for these blade configurations and none should be used The Hot One requires a 240 volt ground...

Page 4: ...drill holes through the drywall in each of the two bottom keyhole positions Insert drywall anchors provided in each hole 6 Insert the drywall anchor screws until completely screwed in Then back each a...

Page 5: ...ck 8 inches wide and long enough to span the distance across the two rafters See Figure 6 Note A 240 volt receptacle must be within six feet of the heater 2 Remove stand from heater by loosening knobs...

Page 6: ...b counterclockwise To increase the room temperature turn the knob clockwise Fan running continuously with intermittent heat Determined by the thermostat setting 1 Press the ON AUTO switch to the ON po...

Page 7: ...instructions on how to have the repair or replacement processed Parts and Service Visit cadetheat com parts service for information on where to obtain parts and service Maintenance As Needed or every...

Page 8: ...rature rise on heater is 40 F 1 Allow heater to cool then push reset 2 Increase the thermostat setting turn ON AUTO switch to AUTO 3 Replace elements 4 Check and correct loose wire 5 Close doors or wi...

Page 9: ...051226 Thermostat 5 050327 Temperature Limit Switch 6 401723 401726 Element RCP402S 1333 1000W 3 req Element RCP502S 1667 1332W 3 req 7 001601 Fan Blade 8 051424 Fan Motor 9 400202 Mounting Stand 10...