background image

Efficienza utile al carico minimo

Useful energy efficiency at minimum load

Rendement utile à la charge minimale

Efficiëntie nuttig voor de minimale last

Nutzleistung für die Mindestlast

Eficiencia útil con la carga mínima

Eficiência útil com carga mínima

Wydajność użytkowa dla minimalnego obciążenia

Užitečná účinnost při minimálním zatížením

Užitočná účinnosť pri minimálnom zaťažení

Eficiența utilă la sarcină minimă

Hasznos hatásfok minimális terhelésen

Izkoristek pri minimalni obremenitvi

Toplinska učinkovitost pri minimalnom opterećenju

Ωφέλιμη απόδοση σε ελάχιστο φορτίο

Полезна ефективност при минимален товар

Naudingasis efektyvumas esant mažiausiai apkrovai

Kasutegur minimaalsel koormusel

Nyttevirkning ved minimal belastning

Nyttoverkningsgraden vid minimibelastning

94,5

94,5

94,5

94,5

Rispettare le avvertenze e le indicazioni di installazione e manutenzione periodica riportate nei capitoli dedicati del manuale di istruzioni

 Comply with the installation and periodic maintenance warnings and indications shown on the dedicated chapters of the instructions manual.

Respecter les mises en garde et les indications d’installation et d’entretien périodique fournies dans les chapitres spécifiques du manuel d’instruction.

Respecteer de waarschuwingen en voorschriften voor de installatie en het periodiek onderhoud aangegeven in de toegewijde hoofdstukken van de handleiding.

Die Warnhinweise und die Anweisungen für die Installation und die regelmäßige Wartung einhalten, die in den entsprechenden Kapiteln des Bedienungshandbuchs enthalten sind.

Cumpla con las advertencias y las indicaciones de instalación y de mantenimiento periódico, indicadas en los capítulos específicos del manual de instrucciones.

Respeitar as advertências e as indicações de instalação e manutenção periódica apresentadas nos capítulos específicos do manual de instruções.

Przestrzegać ostrzeżeń i wskazówek dotyczących instalacji i okresowej konserwacji, podanych w odpowiednich rozdziałach instrukcji obsługi.

Dodržujte upozornění a pokyny pro instalaci a pravidelnou údržbu v odpovídajících kapitolách tohoto návodu k obsluze.

Dodržiavajte upozornenia a pokyny týkajúce sa inštalácie a pravidelnej údržby v osobitných kapitolách tohto návodu na obsluhu.

Respectați avertismentele și indicațiile de instalare și întreținere periodică indicate în capitolele corespunzătoare din manualul de instrucțiuni.

Kövesse a használati útmutató vonatkozó szakaszaiban szereplő beszerelési és karbantartási előírásokat és figyelmeztetéseket.

Upoštevajte opozorila in navodila za nameščanje in redno vzdrževanje, ki so opisana v ustreznih poglavjih navodil za uporabo.

Pridržavajte se upozorenja i uputa za instalaciju i periodično održavanje u posebnim poglavljima priručnika za uporabu.

Τηρείτε τις προειδοποιήσεις και τις οδηγίες εγκατάστασης και περιοδικής συντήρησης που αναφέρονται στα κεφάλαια του εγχειριδίου των οδηγιών.

Спазвайте предупрежденията и указанията за монтаж и периодична поддръжка, посочени в съответните глави на ръководството с инструкции.

Laikykitės specialiuose instrukcijų vadovo skyriuose pateiktų perspėjimų ir montavimo bei periodinės techninės priežiūros nurodymų.

Järgige kasutusjuhendis sisalduvaid juhiseid paigalduseks ja korraliseks hoolduseks.

Overhold advarslerne og instruktionerne for installation og periodisk vedligeholdelse, der er angivet i instruktionsvejledningen.

Respektera de bestämmelser och anvisningar för installation och löpande underhåll som anges i de specifika kapitlen i handboken.

cod

. 89018021 - r

ev

.02

CADEL srl

 

FREEPOINT by Cadel

Via Foresto Sud, 7

31025 Santa Lucia di Piave (TV) - ITALY

www.cadelsrl.com

www.free-point.it

4

Summary of Contents for TILE3 MOON

Page 1: ...EN 2019CADELsrl Allrightsreserved Tuttiidirittiriservati USER MANUAL Pellet Stove WALL3 PLUS TILE3 PLUS MOON LEAN3 PLUS...

Page 2: ...T FICHA DO PRODUTO PL KARTA PRODUKTU CZ INFORMA N LIST V ROBKU SK INFORMA N LIST V ROBKU RO FI A PRODUSULUI HU TERM KISMERTET ADATLAP SL PODATKOVNI LIST IZDELKA HR INFORMACIJSKI LIST PROIZVODA GR BG L...

Page 3: ...erg tique Energie effici ntieklasse Energieeffizienzklasse Clase de eficiencia energ tica Classe de Efici ncia Energ tica Klasa efektywno ci energetycznej T da energetick innosti Trieda energetickej i...

Page 4: ...inkovitosti Indeks energetske u inkovitosti Energijos efektyvumo indeksas Energiat hususe indeks Indeks energieffektivitet Energieffektivitetsindex 128 128 128 128 Efficienza utile alla potenza termic...

Page 5: ...ntenimiento peri dico indicadas en los cap tulos espec ficos del manual de instrucciones Respeitar as advert ncias e as indica es de instala o e manuten o peri dica apresentadas nos cap tulos espec fi...

Page 6: ...PAG 10 16 9 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 10 17 9 19 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TECHNICIANS ONLY SEE SECTION K SETTINGS MENU A PAG 10 17 9 20 COMFORT MODE FUNCTI...

Page 7: ...ive 2009 125 EC Eco Design and where applicable Directives 2014 35 EU LowVoltage 2014 30 EU Electromagnetic Compatibility 2014 53 EU Radio Frequency 2011 65 EU ROhS Read carefully the instruction cont...

Page 8: ...ith 1 meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during...

Page 9: ...ranty to be valid and effective We recommend testing the product before completion with the relative finishes claddings painting of walls etc Installations not meeting the current standards improper u...

Page 10: ...acoustic pollution The company declines all liability for any damage which may be caused directly or indirectly to persons animals or objects as a consequence of non compliance with any prescription...

Page 11: ...provided by national laws transposing the Directive 2012 19 EU Separate waste collection and recycling of unused electric and electronic equipment batteries and accumulators helps to save natural reso...

Page 12: ...onwload wi fi http www free point it it downloads https www pegasoheating com it documenti 9 USE 9 1 INTRODUCTION To have the best performance with the lowest consumption please follow the here descri...

Page 13: ...e display is secured by a screw To allow the display to rotate 90 remove the screw see Fig 6 and Fig 7 Fig 6 Removethescrew Fig 7 Rotatethedisplay 9 3 CONTROL PANEL DISPLAY Menu items Fig 8 Display Fi...

Page 14: ...rew Loading displayed only when the boiler is switched off d Tone e Ext Thermostat activation f Auto Eco activation g OffTime Eco default 5 minutes h Pellet Recipe i Smoke Fan rpm j ComponentsTest dis...

Page 15: ...tton Scroll to Settings using the arrows Press menu to confirm Scroll to Auto Eco activation using the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit g OffT...

Page 16: ...to confirm Scroll to Technical Menu using the arrows Press menu to confirm Select ProductType Service Status Memory Parameters with the keys Press menu to confirm and esc to exit 9 6 INFO MENU Product...

Page 17: ...l shutdown phase which entails the automatic execution of the following stages Pellet loading is stopped The room fan continues to operate until the requested temperature is reached The flue fan is se...

Page 18: ...to maximum heat output 5 and the fans to minimum output 1 this may cause overheating andthe THERMALSAFETY alarmtogooff Comfort Mode this function allows activating deactivating the fans at power 1 Fi...

Page 19: ...rogramme will not appear active in the status screen Continue to program the following days or press ESC to exit Repeat the procedure to program the other timers 9 13 PROGRAMMING EXAMPLES P1 P2 on off...

Page 20: ...C or external thermostat with closed contact for at least 20 to avoid false recalls After 5 minutes from the beginning of the switch off procedure 9 16 SLEEP FUNCTION MAIN MENU The sleep function is...

Page 21: ...ank door is opened LOAD TIME OUT the control unit is equipped with a timer that acoustically warns with 3 beeps that the load time available is over If the user requires more time to finish loading th...

Page 22: ...A05 depression alarm and proceeds to switch off Wait until it switches off then light it again Fig 23 Dooropen Fig 24 deterioratedgasket Fig 25 Timer 90seconds Tooperatecorrectly thestovemustworkwitht...

Page 23: ...temperature 0 C 50 C 38 khz infrared signal Used batteries contain metals which are harmful for the environment they must therefore be disposed of separately in the special containers Fig 27 Remoteco...

Page 24: ...e flame goes out due to lack of fuel and until a minimum level of cooling is reached 11 8 TEMPORARY POWER CUT If the power cut lasts less than 10 the boiler returns to its previous operating status if...

Page 25: ...side fire ducts cleaning clogged hose connection excess flue length unfavou rable weather conditions and clogged stove A08 Abnormal smoke fan operation If the alarm persists contact the service centr...

Page 26: ...and Fig 29 from its seat and empty it from the ash If becessary clean with a pointed object the holes obstructed by encrustations see Fig 30 Fig 31 Ashtrayboxcleaning Fig 32 Burningpotboxcleaning Fig...

Page 27: ...6 Inspectionpanelremoving Unscrew the 2 screws from the galvanised panel see Fig 35 Remove the inspection panel see Fig 36 Fig 37 Cleaningwithabrush Fig 38 Fumechambercleaning Clean the 2 internal fum...

Page 28: ...ably damage the varnish 12 8 CLEANING OF CERAMIC AND STONE PANELS Somestovemodelshasanexternalliningmadeupofceramicorstone Thesepiecesarehandmadethereforetheycouldinevitably present crazings seediness...

Page 29: ...ASE OF ANOMALY 13 1 PROBLEM SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Inc...

Page 30: ...Auger blocked by a foreign object for example nails Clean the auger The auger geared motor is out of order Replace the geared motor Check if on the display there is an ACTIVE ALARM Have the stove che...

Page 31: ...ulty fume tem perature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume pip...