![Cadel SFERA3 11KW Installer Manual Download Page 44](http://html1.mh-extra.com/html/cadel/sfera3-11kw/sfera3-11kw_installer-manual_3537539044.webp)
SFERA3 - PRINCE3 - GLOBE AT - SFERA3 PLUS - SIRE3 PLUS - DOGE3 PLUS - PRINCE3 PLUS - ELISE3 PLUS - VEGA AT - TREND AT - VENUS3 PLUS - JOY AT
44
DESCRIPTION
SIRE
3
PLUS 11 kW DOGE
3
PLUS 11 kW ELISE
3
PLUS 11 kW
WIDTH
54,4 cm
55,4 cm
65 cm
DEPTH
52,3 cm
54 cm
60,3 cm
HEIGHT
104,8 cm
105,6 cm
108 cm
WEIGHT
131 kg
118 kg
138 kg
INTRODUCED THERMAL POWER (Min/Max)
3,5 - 12,3 kW
3,5 - 12,3 kW
3,5 - 12,3 kW
NOMINAL THERMAL POWER (Min/Max)
3,3 - 11 kW
3,3 - 11 kW
3,3 - 11 kW
EFFICIENCY (Min/Max)
93,5 - 89 %
93,5 - 89 %
93,5 - 89 %
FLUE GAS TEMPERATURE (Min/Max)
85 - 197 °C
85 - 197 °C
85 - 197 °C
MAXIMUM FLUE GAS FLOW RATE (Min/Max)
3,7 - 7,6 g/s
3,7 - 7,6 g/s
3,7 - 7,6 g/s
CO EMISSIONS (13% O2) (Min/Max)
0,022 - 0,002 %
0,022 - 0,002 %
0,022 - 0,002 %
OGC EMISSIONS (13% O
2
) (Min/Max)
7 - 2 mg/Nm
3
7 - 2 mg/Nm
3
7 - 2 mg/Nm
3
NOX EMISSIONS (13% O
2
) (Min/Max)
105 - 121 mg/Nm
3
105 - 121 mg/Nm
3
105 - 121 mg/Nm
3
Average CO CONTENT at 13% O
2
(Min/Max)
268 - 23 mg/Nm
3
268 - 23 mg/Nm
3
268 - 23 mg/Nm
3
Average DUST CONTENT at 13% O
2
(Min/Max)
11 - 14 mg/Nm
3
11 - 14 mg/Nm
3
11 - 14 mg/Nm
3
FLUE NEGATIVE PRESSURE (Min/Max)
9 - 12 Pa
9 - 12 Pa
9 - 12 Pa
ON SHARED FLUE
NO
NO
NO
FLUE GAS EXHAUST DIAMETER
Ø80 mm
Ø80 mm
Ø80 mm
FUEL
Pellet Ø6-7 mm
Pellet Ø6-7 mm
Pellet Ø6-7 mm
PELLET HEATING CAPACITY
5 kWh/kg
5 kWh/kg
5 kWh/kg
PELLET HUMIDITY
≤ 10%
≤ 10%
≤ 10%
HEATABLE VOLUME 18/20°C Coeff. 0.045 kW (Min/Max)
79 - 264 m
3
79 - 264 m
3
79 - 264 m
3
HOURLY CONSUMPTION (Min/Max)
0,73 - 2,6 kg/h
0,73 - 2,6 kg/h
0,73 - 2,6 kg/h
HOPPER CAPACITY
22 kg
22 kg
22 kg
RANGE (Min/Max)
8,5 - 30 h
8,5 - 30 h
8,5 - 30 h
POWER SUPPLY
230 V - 50 Hz
230 V - 50 Hz
230 V - 50 Hz
ABSORBED POWER (Max)
360 kW
360 kW
360 kW
STARTER RESISTANCE ABSORBED POWER
300 W
300 W
300 W
MINIMUM EXTERNAL AIR VENT (final cross-section)
80 cm
2
80 cm
2
80 cm
2
SEALED CHAMBER STOVE
SI
SI
SI
EXTERNAL AIR VENT FOR SEALED CHAMBER
60 mm
60 mm
60 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (back/side/
bottom)
200 / 300 / 0 mm
200 / 300 / 0 mm
200 / 300 / 0 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front)
- / 1000 mm
- / 1000 mm
- / 1000 mm
Summary of Contents for SFERA3 11KW
Page 47: ...NOTE...