KOBE - FENICE - SPARK - INDACO - PRINCE
30
USER/TECHNICIAN
PARTS/FREQUENCY
1 DAY
2-3 DAYS
7 DAYS
1 YEAR
UNDER THE USER'S RESPONSIBILITY
Brazier
X
Ash compartment **
X
Glass
X
BY THE QUALIFIED TECHNICIAN
Upper exchanger
X
Lower exchanger
X
Smoke duct
X
Gaskets
X
Door closure operation
X
** Emptying of the ash compartment depends on various factors (pellet type, stove power, stove use, type of installation...); the
exact emptying time will be suggested by experience.
14 IN CASE OF ANOMALY
14.1 PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty to check if the parame-
ters of the mother board correspond to those of the table you own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to
avoi irreparable damages!
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The control display
does not switch on
The stove is without
power supply
Check if the plug is connected.
Burned protection
fuse in the electric
socket
Replace the protection fuses in the electric socket (3.15A-250V).
Faulty control
display
Replace the control display.
Faulty flat cable
Replace the flat cable.
Faulty electronic
board
Replace the mother board.