GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5
26
Fig. 66 - Remove screw 1
Fig. 67 - Remove screw 2
Fig. 68 - Clean with pipe cleaner
• To clean the smoke passage inside the combustion chamber, loosen the 2 screws (see
Fig. 66
and
Fig. 67
) and move the right
wall enough to have access with a pipe cleaner (see
Fig. 68
).
• Clean and vacuum any ash accumulated inside.
• After cleaning, repeat the operation in reverse making sure the gasket is intact and efficient: if necessary, provide for the
replacement with original spare parts.
6.4
HOW TO CLEAN THE ROOM FAN
Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.
MODELS (SPIRIT3 - ATRIUM - MADISON - SOLO 5)
• Remove the door and the front coating (see dedicated chapters).
• Vacuum the ash and dust accumulated in the fan (see
Fig. 69
).
Fig. 69 - Room fan cleaning
MODELS (GRACE3 - ROXY - TABLA)
• Remove the door and the front coating (see dedicated chapters).
• The room fan is fixed to the back of the stove, to remove it loosen the 4 screws behind the stove (see
Fig. 70
).
• Remove the fan and vacuum the ash and dust accumulated in the fan (see
Fig. 71
).