LUCE - ELLE - ARCO
22
Fig. 54 - Fume conduit cleaning
• Remove the inspection lid of the T-union (see
Fig. 54
).
• Extract the ash which has accumulated in the inner.
• After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary
replace it.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
7.4
FUME PASSAGE CLEANING
Every end-of-season (or every 2000 hours of operation) it is necessary to clean the fume passages.
• Remove the door (see the dedicated chapter).
• Push the head of the firebox up, tilt the piece and pull it out.
• Lastly remove the back panel of the firebox (see
Fig. 56
e
Fig. 57
).
Fig. 55 - Remove the hearth head 1
Fig. 56 - Remove the back of the hearth 1
Fig. 57 - Remove the back of the hearth 2
• Clean with a pipe cleaner and suction any ash accumulated inside (see
Fig. 58
).
• Part of the ash will fall into the compartment below the firebox (see
Fig. 59
). See the previous chapter for the cleaning ope-
ration.
Summary of Contents for ARCO 7 T1
Page 30: ...NOTE...
Page 31: ...NOTE...